2021
DOI: 10.3390/diagnostics11091729
|View full text |Cite
|
Sign up to set email alerts
|

The Impact of Phototherapy on the Accuracy of Transcutaneous Bilirubin Measurements in Neonates: Optimal Measurement Site and Timing

Abstract: Transcutaneous bilirubinometer devices are widely applied to assess neonatal hyperbilirubinemia. However, the optimal skin site and timing of transcutaneous bilirubin (TCB) measurements for the strongest correlation with total serum bilirubin (TSB) levels after phototherapy are still unclear. We conducted a retrospective observational study evaluating the correlation of TCB and TSB levels in neonates postphototherapy. The TCB measurements on the forehead and mid-sternum at 0 and 30 min postphototherapy were as… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 37 publications
0
5
0
Order By: Relevance
“…Several studies reported that TcB measurement's effectiveness in assessing TSB is better and more reliable on covered skin areas during or after phototherapy [3,7,12,[20][21][22]. Although three of these studies [12,20,21] used BiliChek, Hulzebos et al [3], and Ho et al [7] used JM-103. Casnocha Lucanova et al [5] utilized Minolta JM-103.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Several studies reported that TcB measurement's effectiveness in assessing TSB is better and more reliable on covered skin areas during or after phototherapy [3,7,12,[20][21][22]. Although three of these studies [12,20,21] used BiliChek, Hulzebos et al [3], and Ho et al [7] used JM-103. Casnocha Lucanova et al [5] utilized Minolta JM-103.…”
Section: Discussionmentioning
confidence: 99%
“…The abdomen, interscapular, and gluteal regions are used less frequently for TcB measurements [3,4,10,11]. TcB measurement in areas covered by a diaper or commercialized tool can avoid underestimating the TSB levels in infants undergoing phototherapy [7]. Several studies reported that TcB measurements from covered sites during phototherapy were more reliable than those from exposed areas [3,4,[12][13][14].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…This necessitates an investigation into the challenges confronting the accuracy of TcB during phototherapy and the formulation of strategies to surmount these constraints. Moreover, the exploration of alternative techniques or modifications to existing technology capable of furnishing precise and reliable bilirubin measurements during phototherapy is imperative ( 223 ). A comprehensive understanding of the photo breakdown of bilirubin concerning TcB measurements and the development of techniques to account for this phenomenon would significantly enhance the clinical applicability of TcB devices.…”
Section: Open Problems For Research On Transcutaneous Bilirubinometersmentioning
confidence: 99%
“…[20][21][22][23][24][25][26][27][28][29][30][31][32][33][34] Also, several of the included studies have repeated paired measurements per neonate. 23,[28][29][30]33,35,38,39,44,45,[50][51][52][53][54][55][56][57][58][59][60][61][62][63] In earlier literature, it is postulated that TcB values in the higher ranges (above 256 lmol/L [3 mg/dL]) are not reliable. 7 We were not able because of lack of original data to separately assess the agreement in the higher ranges.…”
Section: Ementioning