2019
DOI: 10.2478/rtuect-2019-0001
|View full text |Cite
|
Sign up to set email alerts
|

The Impact of Parallel Energy Consumption on the District Heating Networks

Abstract: The aim of this study is to evaluate and compare the impacts of heat recovery ventilation (HRV) and exhaust air heat pump (EAHP)-based solutions used in renovated buildings, which make it possible to reach performance class C in district heating (DH) area CO2 emissions, primary energy consumption and total energy costs for consumers. Evaluation is based on the methodology presented in the previous research paper [1]. Calculation results show that the use of EAHP has a negative impact on DH sustainability (heat… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
12
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 14 publications
(12 citation statements)
references
References 18 publications
0
12
0
Order By: Relevance
“…The latest overview of the existing DH systems, found in the Heat Roadmap Europe 2050 (a study covering the Europ ean Union member states) has shown that about 60 million of European residents, 287 regions and 141 cities are connected to DH [3]. In some European countries, where the climate is traditionally colder, such as Northern European countries (Latvia, Estonia, Lithuania) [4], [5] or Nordic countries (Denmark, Sweden and Finland) more than half of the residents have their heat provided by DH [6]. The DH system must transform and advance in order to be able to compete with other heat supply solutions, in accordance with the new conditions associated with renewable energy sources and buildings with low heat demand, as well as offer excellent customer service.…”
Section: Introductionmentioning
confidence: 99%
“…The latest overview of the existing DH systems, found in the Heat Roadmap Europe 2050 (a study covering the Europ ean Union member states) has shown that about 60 million of European residents, 287 regions and 141 cities are connected to DH [3]. In some European countries, where the climate is traditionally colder, such as Northern European countries (Latvia, Estonia, Lithuania) [4], [5] or Nordic countries (Denmark, Sweden and Finland) more than half of the residents have their heat provided by DH [6]. The DH system must transform and advance in order to be able to compete with other heat supply solutions, in accordance with the new conditions associated with renewable energy sources and buildings with low heat demand, as well as offer excellent customer service.…”
Section: Introductionmentioning
confidence: 99%
“…As a rule, economic criteria are used: if the cost of heating the consumer from a centralized source is lower than from an individual source, then its connection to DHS is considered as economically feasible [12]. This problem becomes even more topical when implementation the technology of parallel consumption wherein the heat consumer connected to the DHS also consumes heat produced by other energy sources [13], [14]. Heat supply planning is usual and legislated in Europe.…”
Section: Introductionmentioning
confidence: 99%
“…Reverse Osmosis (RO) is the most widely used method in the world: in or der to operate this technology, it is necessary to think about the source of energy used as well as the amount of reverse osmosis required energy. Thus, it is the only electricity consumed mainly by high pressure pumps [6]. Such energy plays a very important role in the cost of producing fresh water from seawater or brackish water.…”
Section: Introductionmentioning
confidence: 99%