2021
DOI: 10.1111/andr.12971
|View full text |Cite
|
Sign up to set email alerts
|

The impact of five years storage/biobanking at −80°C on mouse spermatozoa fertility, physiology, and function

Abstract: Background We previously demonstrated how mouse spermatozoa can be efficiently stored for two years in a −80°C freezer, maintaining their ability to fertilize mouse eggs. Objectives The main objective here was to evaluate the effects of five years at −80°C compared to liquid nitrogen storage (LN2, control condition) on mouse sperm viability, physiological parameters, and fertilization capacity. Materials and methods Three different strains were used: C57BL/6N, C57BL/6J and CD1. Flow cytometry experiments were … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(1 citation statement)
references
References 35 publications
0
1
0
Order By: Relevance
“…Compensation was assessed using CompBeads and FACSuite FC Beads (BD Biosciences) and single stained fluorescent samples. Data were analyzed first using FACSuite v 1.0.5 (BD Biosciences) software, and then FcsWizard Software was used to convert .fcs data to .csv format in order to perform an exhaustive analysis of the fluorescence emitted from every single spermatozoon for the various fluorescence probes [66]. To that, the columns "FCS", "SSC", "Fluo-4AM", "PI", "DilC12", "Mito" and "NIR" with the data from the 100,000 events acquired, were selected and filtered following these criteria: forward scatter (FCS) between 35,000 and 135,000 arbitrary units (a.u); side scatter (SSC) between 20,000 and 145,000 a.u; Fluo 3-AM, M540 and Mitotracker Red >0 a.u; PI between 0 and 30,000 a.u; and near infrared between 0 and 20,000 a.u.…”
Section: Flow Cytometry Analysis Of Intracellular Calcium Concentrati...mentioning
confidence: 99%
“…Compensation was assessed using CompBeads and FACSuite FC Beads (BD Biosciences) and single stained fluorescent samples. Data were analyzed first using FACSuite v 1.0.5 (BD Biosciences) software, and then FcsWizard Software was used to convert .fcs data to .csv format in order to perform an exhaustive analysis of the fluorescence emitted from every single spermatozoon for the various fluorescence probes [66]. To that, the columns "FCS", "SSC", "Fluo-4AM", "PI", "DilC12", "Mito" and "NIR" with the data from the 100,000 events acquired, were selected and filtered following these criteria: forward scatter (FCS) between 35,000 and 135,000 arbitrary units (a.u); side scatter (SSC) between 20,000 and 145,000 a.u; Fluo 3-AM, M540 and Mitotracker Red >0 a.u; PI between 0 and 30,000 a.u; and near infrared between 0 and 20,000 a.u.…”
Section: Flow Cytometry Analysis Of Intracellular Calcium Concentrati...mentioning
confidence: 99%