2020
DOI: 10.1016/j.ejvsvf.2020.08.002
|View full text |Cite
|
Sign up to set email alerts
|

The Impact of EndoAnchor Penetration on Endograft Structure: First Report of Explant Analysis

Abstract: Objective The adjunctive use of Heli-FX EndoAnchors (EAs) in endovascular aneurysm repair has been proposed for the treatment or prevention of type Ia endoleaks. The aim of this study was to evaluate the impact of the penetration of EAs on endograft textile structure from two aortic endografts that had been explanted for persistent type Ia endoleak despite the implantation of EAs. Methods An Aorfix aortic endograft was implanted in an 85 year old man. Six months later, … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
4
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 10 publications
0
4
0
Order By: Relevance
“…A study of explanted endografts found that suboptimal placement, such as with noncircumferential positioning, or deployment issues, such as the angle or depth of penetration, of endoanchors resulted in structural damage to the stent. 27 This indicates that the technical aspects of endoanchor placement should be thoroughly considered before use.…”
Section: Discussionmentioning
confidence: 99%
“…A study of explanted endografts found that suboptimal placement, such as with noncircumferential positioning, or deployment issues, such as the angle or depth of penetration, of endoanchors resulted in structural damage to the stent. 27 This indicates that the technical aspects of endoanchor placement should be thoroughly considered before use.…”
Section: Discussionmentioning
confidence: 99%
“… Cleaning of the VG according to our standardized protocol that was chemical using sodium hypochlorite until 2017 11 and became papain-based enzymatic after. 12 After cleaning, VGs were once again photographed and analyzed macroscopically to determine the area where the ruptures occurred. The analysis was completed by carrying out a microscopical examination using a Keyence VHX-600 digital microscope (Keyence France).…”
Section: Methodsmentioning
confidence: 99%
“…Cleaning of the VG according to our standardized protocol that was chemical using sodium hypochlorite until 2017 11 and became papain-based enzymatic after. 12 …”
Section: Methodsmentioning
confidence: 99%
“…The study by Grandhomme et al. 1 provides an excellent insight into textile structure damage related to EndoAnchor use. Two patients with complete aortic wall and endograft explantation were analysed.…”
mentioning
confidence: 99%