2016
DOI: 10.1016/j.jcms.2016.02.005
|View full text |Cite
|
Sign up to set email alerts
|

The impact of different cone beam computed tomography and multi-slice computed tomography scan parameters on virtual three-dimensional model accuracy using a highly precise ex vivo evaluation method

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
9
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 14 publications
(9 citation statements)
references
References 26 publications
0
9
0
Order By: Relevance
“…Although veterinary studies evaluating anatomical accuracy and comparison between methods (MSCT and CBCT) are lacking, their reconstruction algorithms provide isometrically similar and accurate images for bone, as demonstrated in previous studies in the human field. 3,4 The morphometric data documented in this study identified differences in the conformation of the mandibular fossa, in the head of the mandible and in joint congruity between two groups of cats with different skull conformations. The findings were of statistical significance, despite of the small number of individuals, which was a limitation of the study.…”
Section: Discussionmentioning
confidence: 64%
See 1 more Smart Citation
“…Although veterinary studies evaluating anatomical accuracy and comparison between methods (MSCT and CBCT) are lacking, their reconstruction algorithms provide isometrically similar and accurate images for bone, as demonstrated in previous studies in the human field. 3,4 The morphometric data documented in this study identified differences in the conformation of the mandibular fossa, in the head of the mandible and in joint congruity between two groups of cats with different skull conformations. The findings were of statistical significance, despite of the small number of individuals, which was a limitation of the study.…”
Section: Discussionmentioning
confidence: 64%
“…Although veterinary studies evaluating anatomical accuracy and comparison between methods (MSCT and CBCT) are lacking, their reconstruction algorithms provide isometrically similar and accurate images for bone, as demonstrated in previous studies in the human field. 3,4…”
Section: Discussionmentioning
confidence: 99%
“…A threshold tool is available so that the examiner can change the airway space-filling degree according to visual inspection. Since there is no standard protocol for these instruments and measurements, [8,14,[20][21][22] the calibrated observer calculated with the preset (25) and the best value that visually could fill the airway borders.…”
Section: Discussionmentioning
confidence: 99%
“…Some protocols have a higher resolution (smaller voxel sizes) but also result in greater exposure to radiation for patient. [13,20] It is prudent that the least needed resolution should be used to reduce patient exposure to radiation. This study compared the airway volume acquired with three voxel resolutions -0.2 mm, 0.25 mm, and 0.4 mm.…”
Section: Discussionmentioning
confidence: 99%
“…The previous studies recommend the use of small scan fields and a small voxel size to optimize quality of 3D model. 31,32 The greatest disadvantage of the AR creation process is the storage in cloud space. Using an open-source software, the space is limited to 100 MB.…”
Section: Discussionmentioning
confidence: 99%