2018
DOI: 10.1186/s13014-018-1033-y
|View full text |Cite
|
Sign up to set email alerts
|

The impact of contour variation on tumour control probability in anal cancer

Abstract: BackgroundWhile intensity modulated radiotherapy (IMRT) has been widely adopted for the treatment of anal cancer (AC), the added contour complexity poses potential risks. This study investigates the impact of contour variation on tumour control probability (TCP) when using IMRT for AC.MethodsNine Australian centres contoured a single computed tomography dataset of a patient with AC. The same optimised template-based IMRT planning protocol was applied to each contour set to generate nine representative treatmen… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 34 publications
0
3
0
Order By: Relevance
“…Inaccurate demarcation may lead to a geographic miss of a high-risk region and hence, reduced local control and poor survival. 25 This also exposes the surrounding normal tissues to excess doses of radiation beyond their tolerance limits, resulting in higher toxicities. This severity of toxicity warrants the use of precise techniques of delivering radiation.…”
Section: Discussionmentioning
confidence: 99%
“…Inaccurate demarcation may lead to a geographic miss of a high-risk region and hence, reduced local control and poor survival. 25 This also exposes the surrounding normal tissues to excess doses of radiation beyond their tolerance limits, resulting in higher toxicities. This severity of toxicity warrants the use of precise techniques of delivering radiation.…”
Section: Discussionmentioning
confidence: 99%
“…[16][17][18] Inter-observer variability in the definition of radiotherapy treatment volumes can impair disease control and treatment outcomes. 19,20 PET imaging reduces this interobserver difference, but it does not remove it entirely. 21,22 Manual definition and identification of the tumour edge is dependent on the observer's skills, experience, contouring system and window settings used.…”
Section: Introductionmentioning
confidence: 98%
“…The requirements of fast pace and accurate planning will put the entire workflow under high pressure, thus increasing planning errors. Moreover, the planner's experience level and preferences would result in significant inter-and intra-observer variations [8,9], further introducing more uncertainties in treatment planning and dose delivery [10][11][12].…”
Section: Introductionmentioning
confidence: 99%