2011
DOI: 10.1016/j.clinbiochem.2011.05.007
|View full text |Cite
|
Sign up to set email alerts
|

The ImmunoCAP ISAC molecular allergology approach in adult multi-sensitized Italian patients with respiratory symptoms

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

5
122
1

Year Published

2012
2012
2022
2022

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 92 publications
(128 citation statements)
references
References 13 publications
5
122
1
Order By: Relevance
“…Inter-assay CV of ISAC 103 was > 100%, 33% and 13.2% for Low, Medium and High ISU-E categories, respectively [17]; however, definitions of the Low and Medium categories for ISAC 103 differ from the current definitions for ISAC 112. These previous estimates of total variation were based on within-and between-assay estimates of variability obtained using a reproducibility study where all assays were run at one site [17]. In the present study the categoryspecific estimates of variation ranged from 22 to 27% and the overall estimate, CV Total , was 25.5%.…”
Section: Discussionmentioning
confidence: 97%
See 1 more Smart Citation
“…Inter-assay CV of ISAC 103 was > 100%, 33% and 13.2% for Low, Medium and High ISU-E categories, respectively [17]; however, definitions of the Low and Medium categories for ISAC 103 differ from the current definitions for ISAC 112. These previous estimates of total variation were based on within-and between-assay estimates of variability obtained using a reproducibility study where all assays were run at one site [17]. In the present study the categoryspecific estimates of variation ranged from 22 to 27% and the overall estimate, CV Total , was 25.5%.…”
Section: Discussionmentioning
confidence: 97%
“…Fluorescence intensity is measured by a microarray scanner, converted to arbitrary concentration units, and is then displayed both in arbitrary units ISAC Standardized Units for IgE (ISU-E), being internally cross-calibrated to ImmunoCAP singleplex kU A /l, and as semi-quantitative values (classes). The technical and clinical performances of the ISAC 112 have been validated in several studies that -depending on the allergen component -report comparable results to quantitative singleplex ImmunoCAP allergen component tests [3,[10][11][12][13][14][15][16][17][18][19].…”
Section: Introductionmentioning
confidence: 99%
“…The first allergen microarray [Immuno Solid-Phase Allergen Chip (ISAC)] was described in 2002 [23]. Since then the assay was improved, the number of components increased and its clinical use become widespread [18,[24][25][26]. Recently, other platforms were developed and described: the MedALL [27] and the Microtest [28].…”
Section: Multiplexed Diagnostics (Mpd)mentioning
confidence: 99%
“…It has many advantages and results are close but not identical to classical immunoassays [10] (WAO Position Paper, in press). However, for some allergens [11][12][13] and for low IgE levels [14] it may not be sufficiently sensitive. Moreover, important allergens are not included on the ImmunoCAP ISAC chip.…”
Section: Introductionmentioning
confidence: 99%