The imaging performance of a storage phosphor system for dental radiography

Abstract: Direct digital imaging systems are becoming increasingly common in dental radiography. The majority of these systems are based on charge coupled device (CCD) technology. A relatively new system, based on photo-stimulable phosphor luminescence (PSPL), is now commercially available. This system appears to overcome some of the restrictions of CCD systems including those associated with the bulky detector, connecting wire, limited image size and limited exposure latitude. A physical evaluation of the PSPL system w… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
25
0
2

Year Published

1999
1999
2017
2017

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 67 publications
(62 citation statements)
references
References 5 publications
(7 reference statements)
0
25
0
2
Order By: Relevance
“…A digitalization error (causing lack of reproducibility) of pixel values would be deleterious in these situations because it would attribute pixel values that differ from those corresponding to a true change that occurred in the patient. Apparently, photon noise originating from Xrays may be one factor that could contribute to the large digitalization error observed for photostimulable plates of the Digora system 4,6,17,18 . As observed in Table 2 through Table 5, the lower exposure times (0.3; 0.2; 0.1; 0.05 s) showed, in general, higher pixel variability.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…A digitalization error (causing lack of reproducibility) of pixel values would be deleterious in these situations because it would attribute pixel values that differ from those corresponding to a true change that occurred in the patient. Apparently, photon noise originating from Xrays may be one factor that could contribute to the large digitalization error observed for photostimulable plates of the Digora system 4,6,17,18 . As observed in Table 2 through Table 5, the lower exposure times (0.3; 0.2; 0.1; 0.05 s) showed, in general, higher pixel variability.…”
Section: Discussionmentioning
confidence: 99%
“…Finally, the image is obtained electronically, eliminating chemical processing, and the plates are also reutilizable 6,11 .…”
Section: Introductionmentioning
confidence: 99%
“…It is most often integrated with other metrics to assess image quality for specific tasks, 6 , 7 , 8 , 9 and has been commonly utilized in the development, characterization, optimization, and comparison of many new imaging technologies such as computed radiography, (10) digital mammography, 11 , 12 storage phosphors for dental X‐ray, (13) and other devices in a preclinical 14 , 15 and clinical 16 , 17 environment.…”
Section: Introductionmentioning
confidence: 99%
“…This is especially true for intra-oral radiography, where a significant reduction of radiation dose has been reported. [1][2][3][4][5] For extraoral digital radiography however, a smaller reduction can be expected because of the already low dose thanks to the use of intensifying screens and fast film-screen combinations in conventional radiography. For digital panoramic radiography, different amounts of dose reduction have been reported.…”
Section: Introductionmentioning
confidence: 99%