2019
DOI: 10.1016/j.quaint.2018.09.008
|View full text |Cite
|
Sign up to set email alerts
|

The iBox-FC: A new containment vessel for Itrax X-ray fluorescence core-scanning of freeze cores

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0

Year Published

2019
2019
2021
2021

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 10 publications
(13 citation statements)
references
References 15 publications
0
13
0
Order By: Relevance
“…Error bars show the precision of I rs (ip)/I d (ip) (AEsigma %: absolute error). Gregory et al, 2019) and Avaatech XRF core scanner (Avaatech BV, Alkmaar, The Netherlands; Hennekam et al, 2019). The concentrations of eight elements derived from the resin-corrected XRF intensities using the calibration lines show similar patterns on the concentrations as measured using the conventional bead-XRF and corder analyses ( Fig.…”
Section: Calibration Of Micro-x-ray Fluorescence Scanning Spectroscopmentioning
confidence: 75%
See 1 more Smart Citation
“…Error bars show the precision of I rs (ip)/I d (ip) (AEsigma %: absolute error). Gregory et al, 2019) and Avaatech XRF core scanner (Avaatech BV, Alkmaar, The Netherlands; Hennekam et al, 2019). The concentrations of eight elements derived from the resin-corrected XRF intensities using the calibration lines show similar patterns on the concentrations as measured using the conventional bead-XRF and corder analyses ( Fig.…”
Section: Calibration Of Micro-x-ray Fluorescence Scanning Spectroscopmentioning
confidence: 75%
“…On the other hand, the multivariate log‐ratio calibration (MLC) approach is a useful method for correcting detection efficiency as well as matrix effect, which allows conversion from corrected intensities to concentrations based on the line y = x (Weltje et al ., ). Studies that recently applied this approach and show successful results are reported for the Itrax‐XRF core logger (Cox Analytical Systems; Gregory et al ., ) and Avaatech XRF core scanner (Avaatech BV, Alkmaar, The Netherlands; Hennekam et al ., ).…”
Section: Results and Assessmentmentioning
confidence: 99%
“…The core was prepared for Itrax-XRF analysis following procedures outlined by Gregory et al (2019b). Core CON01 was cut length-wise using a ripsaw into an approximately 3cm-wide section, then subdivided into nine approximately 12.5-cm-long slabs using a finebladed hacksaw so as to minimize loss of information; cores were subsequently recleaned to eliminate contamination that may have occurred during slabbing.…”
Section: Geochemical Analysismentioning
confidence: 99%
“…Core CON01 was cut length-wise using a ripsaw into an approximately 3cm-wide section, then subdivided into nine approximately 12.5-cm-long slabs using a finebladed hacksaw so as to minimize loss of information; cores were subsequently recleaned to eliminate contamination that may have occurred during slabbing. Core slabs were stored wrapped in clingfilm for transport to McMaster University where they were analyzed at the McMaster Core-Scanning facility using purpose-designed insulated boxes capable of keeping core material frozen for up to 2 hours (Gregory et al 2019b).…”
Section: Geochemical Analysismentioning
confidence: 99%
See 1 more Smart Citation