2022
DOI: 10.11591/ijeecs.v25.i3.pp1236-1245
|View full text |Cite
|
Sign up to set email alerts
|

The harmonic reduction techniques in shunt active power filter when integrated with non-conventional energy sources

Abstract: <span>The article covers the control techniques of shunt active filters using switching devices using artificial neural network (ANN) Theory. The basic idea is to achieve perfect disturbance minimization in both steady and transient states. The paper talks about a four-legged converter with a voltage source that can adjust for biased currents and harmonic elements caused by non-linear loads. A shunt connected active filter is used to minimise harmonic currents. The new proposed ANN controller for the imp… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 26 publications
0
5
0
Order By: Relevance
“…Figure 1 is a PV system's configuration with the proposed inverter. The system comprises PV array, charge controller, battery, the proposed inverter, and AC load [23], [24]. The basic diagram of the three-phase two-step inverter is displayed in Figure 2.…”
Section: Materials and Methods 21 Photovoltaic Inverter Topologymentioning
confidence: 99%
“…Figure 1 is a PV system's configuration with the proposed inverter. The system comprises PV array, charge controller, battery, the proposed inverter, and AC load [23], [24]. The basic diagram of the three-phase two-step inverter is displayed in Figure 2.…”
Section: Materials and Methods 21 Photovoltaic Inverter Topologymentioning
confidence: 99%
“…The capacitor's design values can be determined using the expressions identified in ( 27)- (30). The selfresistances of reactors are chosen such that their corresponding reactors are revealing almost pure reactive responses at the AC source fundamental frequency.…”
Section: The Harmonic-treated Tcr Based Svcmentioning
confidence: 99%
“…This filter was designed to improve the power quality of the AC grid via compensating harmonic currents and reactive power. A single-phase voltage source converter equipped with a shunt active filter was proposed by [30] to accomplish optimal minimization of current disturbance and harmonic reduction. A DSTATCOM equipped with Icos𝜙 controlling modality was proposed by [30] to enhance voltage regulation, power factor improvement, load balancing, and harmonic suppression of non-linear loads, whereas a system in [31].…”
Section: Introductionmentioning
confidence: 99%
“…The reactances connected in star form were used for compensating reactive currents, whereas those connected in delta for were exploited for balancing the active components of line currents. Active filters were introduced in [23] for the purposes of treating harmonic current components associating nonlinear loads, whereas in [24], a shunt active filter was provided to a single-phase converter to achieve significant reduction in harmonic current components. A DSTATCOM was introduced in [25] for power quality purposes.…”
Section: Introductionmentioning
confidence: 99%