1963
DOI: 10.1016/0032-3861(63)90054-5
|View full text |Cite
|
Sign up to set email alerts
|

The glass transition temperature of polymeric sulphur

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

4
39
2

Year Published

1966
1966
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 35 publications
(45 citation statements)
references
References 5 publications
4
39
2
Order By: Relevance
“…More importantly, at variance with the α-relaxation plateau G ∞ , the plateau value G c turns out to have significant temperature dependence around T λ and, in spite of its small value (G c ≈10 −3 G ∞ ), the large contribution to η is brought about by the large value of τ c . The discovery of this low frequency plateau above T λ also allows to rationalize the abrupt decay of the shear modulus measured by stress relaxation technique [23], in the range −40 < T < −30 o C, in sulphur rapidly quenched from T=250 o C, and substantiates the hypothesis made in Ref. [22].…”
supporting
confidence: 87%
See 3 more Smart Citations
“…More importantly, at variance with the α-relaxation plateau G ∞ , the plateau value G c turns out to have significant temperature dependence around T λ and, in spite of its small value (G c ≈10 −3 G ∞ ), the large contribution to η is brought about by the large value of τ c . The discovery of this low frequency plateau above T λ also allows to rationalize the abrupt decay of the shear modulus measured by stress relaxation technique [23], in the range −40 < T < −30 o C, in sulphur rapidly quenched from T=250 o C, and substantiates the hypothesis made in Ref. [22].…”
supporting
confidence: 87%
“…In this respect, we believe that the large difference G ∞ −G c that we observe can be related with the decay of the shear modulus reported in Ref. [23] : the value of the plateau in G c (T ) reported here is ≈ 8 · 10 5 Pa, while in the decay observed in Ref. [23] the lowest measured value upon heating is ≈ 6 · 10 4 Pa. We consider such difference as remarkably small, in view of the large variation of the elastic modulus from the solid to the polymeric regime.…”
supporting
confidence: 81%
See 2 more Smart Citations
“…Rheometric measurements on quick quenched semi polymeric sulphur samples [20] indicate (low temperature trend) a value of G ∞ of about 10 10 Pa, while suggesting (high 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 F o r P e e r R e v i e w O n l y temperature trend) a superior limit for G ∞1 of about 10 6 Pa. Assuming these values, we can consider G ∞1 to be very small when compared to G ∞ .…”
Section: Resultsmentioning
confidence: 99%