2013
DOI: 10.1016/j.nimb.2013.07.063
|View full text |Cite
|
Sign up to set email alerts
|

The FRS Ion Catcher – A facility for high-precision experiments with stopped projectile and fission fragments

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
48
0
1

Year Published

2014
2014
2022
2022

Publication Types

Select...
4
3
1

Relationship

1
7

Authors

Journals

citations
Cited by 116 publications
(51 citation statements)
references
References 19 publications
0
48
0
1
Order By: Relevance
“…The exotic nuclides produced and separated in flight at relativistic energies are slowed down with a mono-energetic degrader system, implanted in the cryogenic stopping cell (CSC) and afterwards, extracted within ~ 20 ms, analyzed and cooled with a gas-filled RFQ and finally injected into the MR-TOF-MS [39], see section above. In an MR-TOF-MS the exotic nuclides are analyzed in flight time coordinate according to their m/q ratio.…”
Section: The Mr-tof-msmentioning
confidence: 99%
“…The exotic nuclides produced and separated in flight at relativistic energies are slowed down with a mono-energetic degrader system, implanted in the cryogenic stopping cell (CSC) and afterwards, extracted within ~ 20 ms, analyzed and cooled with a gas-filled RFQ and finally injected into the MR-TOF-MS [39], see section above. In an MR-TOF-MS the exotic nuclides are analyzed in flight time coordinate according to their m/q ratio.…”
Section: The Mr-tof-msmentioning
confidence: 99%
“…Offline experiments have been performed at Oak Ridge [22] and spectra of short-lived nuclides (with already known mass values) were taken at RIKEN [13] and at GSI [14]. Beyond these…”
Section: Mr-tof Studies At Isoltrapmentioning
confidence: 99%
“…In order to speed up and to enhance the purification, isobaric mass separation by use of a multi-reflection time-of-flight (MR-ToF) mass analyzer [10] has recently been added to the experimental event sequence [11]. In addition, this device can be used as a mass spectrometer of its own [12][13][14]. It allows precision measurements as well as ion-intensity monitoring at high, i.e.…”
Section: Introductionmentioning
confidence: 99%
“…The goal is to stop effectively the isotopically separated exotic nuclei in the He gas volume. In the first experiments with the CSC [20] with uranium projectile fragments produced at 1000 A·MeV, the stopping efficiency after range-bunching with a monoenergetic degrader system placed at the central focal plane of the FRS was about 25 %. This experimental result is deduced from range measurements of 223 Th fragments.…”
Section: -P4mentioning
confidence: 99%
“…In this spirit, as mentioned above, we have tested the combination of the cryogenic gasstopping cell and multiple-reflection time-of-flight mass spectrometer [20].…”
Section: Inpc 2013mentioning
confidence: 99%