APEC. Seventeenth Annual IEEE Applied Power Electronics Conference and Exposition (Cat. No.02CH37335)
DOI: 10.1109/apec.2002.989344
|View full text |Cite
|
Sign up to set email alerts
|

The forward converter: from the classic to the contemporary

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
43
0
3

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 112 publications
(46 citation statements)
references
References 10 publications
0
43
0
3
Order By: Relevance
“…In order to make the comparison clear, the key variables of equations (7) and (8) are both the input voltage V in in that the input voltages are the same for different converters and the duty cycles and turn ratios are different. According to (7) and (8), the ripples between the two schemes are plotted in Fig.7. ( )…”
Section: B Output Current Ripplesmentioning
confidence: 99%
See 2 more Smart Citations
“…In order to make the comparison clear, the key variables of equations (7) and (8) are both the input voltage V in in that the input voltages are the same for different converters and the duty cycles and turn ratios are different. According to (7) and (8), the ripples between the two schemes are plotted in Fig.7. ( )…”
Section: B Output Current Ripplesmentioning
confidence: 99%
“…The current ripple of the parallel hybrid forward converter is described in (7). Equation (8) shows the current ripple of the proposed hybrid rectifier with two intervals divided according to the input voltages range corresponding to case 1 and case 2.…”
Section: B Output Current Ripplesmentioning
confidence: 99%
See 1 more Smart Citation
“…Single-switch forward converter is widely used due to the advantage of simple structure and low cost [1]. But it has disadvantage of high voltage stress of switch, in order to overcome the disadvantage, dual-switch forward topology is proposed.…”
Section: Introductionmentioning
confidence: 99%
“…However, the conversion efficiency of the converter will not be greatly improved. In recent years, active-clamping techniques have been proposed for both types of converters [2]- [14] to absorb the energy stored in the leakage inductance and to suppress the voltage spikes on the switch. Furthermore, in the forward converter, it completes the energy reset process.…”
Section: Introductionmentioning