2021
DOI: 10.1089/ten.tec.2021.0163
|View full text |Cite
|
Sign up to set email alerts
|

The Foreign Body Response to an Implantable Therapeutic Reservoir in a Diabetic Rodent Model

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
15
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
6
1

Relationship

3
4

Authors

Journals

citations
Cited by 9 publications
(15 citation statements)
references
References 73 publications
0
15
0
Order By: Relevance
“…The capsular region (Fig. 3C) directly beneath the dome of the device and overlying membrane was reconstructed using segmentation (Mimics, Materialise, Leuven) from micro-computed tomography (micro-CT) ( 1 , 35 ). A time-dependent increase in mean capsular thickness (Fig.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The capsular region (Fig. 3C) directly beneath the dome of the device and overlying membrane was reconstructed using segmentation (Mimics, Materialise, Leuven) from micro-computed tomography (micro-CT) ( 1 , 35 ). A time-dependent increase in mean capsular thickness (Fig.…”
Section: Resultsmentioning
confidence: 99%
“…Previous studies have noted that the fibrotic capsule continues to mature and develop for months after implantation, with the permeability decreasing as the capsule becomes denser, further inhibiting drug release ( 18 ). To determine an actuation regimen that can overcome a more developed fibrotic capsule, capsular porosity was determined using histological analysis of samples from previous work ( 18 , 35 ) at days 28 and 58 (similarities in fibrotic capsules validated across rodent species and sex; table S11 and fig. S9).…”
Section: Discussionmentioning
confidence: 99%
“…Additionally, patient comfort is an important consideration with devices of this size and shape and this metric would need to be tested in a clinical trial setting. This material also has excellent manufacturing flexibility where reservoir shape, size and volume can be easily modified [ 51 , 52 , 54 , 55 ]. Additionally, an inner support structure can be easily added to support dispersion of the islets throughout the device and prevent islet clumping [ 51 , 56 , 57 ].…”
Section: Discussionmentioning
confidence: 99%
“… Co-transplantation of Fas ligand with streptavidin (SA-FasL) microgels and islets [490] . Robotic drug delivery technique Dynamic Soft Reservoir (DSR) that utilized mechanical oscillation to mitigate fibrotic capsule formation [224] , [491] . …”
Section: Current State Of Islet Transplantationmentioning
confidence: 99%
“…Dynamic Soft Reservoir (DSR) that utilized mechanical oscillation to mitigate fibrotic capsule formation [224] , [491] .…”
Section: Current State Of Islet Transplantationmentioning
confidence: 99%