2019
DOI: 10.1007/s10853-019-03350-w
|View full text |Cite
|
Sign up to set email alerts
|

The fluorescence self-healing mechanism and temperature-sensitive properties of a multifunctional phosphosilicate phosphor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
6
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 10 publications
(6 citation statements)
references
References 49 publications
0
6
0
Order By: Relevance
“…As for the MGS host, the absorption band was found to be located between 200 and 375 nm. In a different manner, the Mn 4+ -doped samples possessed not only the host absorption but also absorption bands over the 400–600 nm range arising from the intra-d-shell electronic transitions of Mn 4+ ions . Due to the improvement of the Mn 4+ doping concentration, the absorption band intensities were obviously enhanced.…”
Section: Resultsmentioning
confidence: 98%
See 1 more Smart Citation
“…As for the MGS host, the absorption band was found to be located between 200 and 375 nm. In a different manner, the Mn 4+ -doped samples possessed not only the host absorption but also absorption bands over the 400–600 nm range arising from the intra-d-shell electronic transitions of Mn 4+ ions . Due to the improvement of the Mn 4+ doping concentration, the absorption band intensities were obviously enhanced.…”
Section: Resultsmentioning
confidence: 98%
“…In a different manner, the Mn 4+ -doped samples possessed not only the host absorption but also absorption bands over the 400−600 nm range arising from the intra-dshell electronic transitions of Mn 4+ ions. 42 Due to the improvement of the Mn 4+ doping concentration, the absorption band intensities were obviously enhanced. It is clear that the incorporation of Mn 4+ exerted distinct effects on the absorption of the MGS host.…”
Section: ■ Results and Discussionmentioning
confidence: 99%
“…The change in the lifetime of Eu 2+ emission upon Tb 3+ concentration was determined to study the energy transfer efficiency. [34][35][36][37][38] As disclosed in Fig. 5b, the lifetime decreases monotonously with the increasing Tb 3+ concentration.…”
Section: Resultsmentioning
confidence: 66%
“…Sensing temperature based on luminescence materials attracts many attentions [1][2][3][4][5][6][7][8][9]. Such thermometry monitors temperature based on the change of peak shape/intensity/shift, fluorescence lifetimes, and luminescence intensity ratio (FIR) of certain phosphors against temperature, and has the advantages of high sensitivity, remote observation, and good spatial resolution [10].…”
Section: Introductionmentioning
confidence: 99%