2011
DOI: 10.5194/acp-11-5491-2011
|View full text |Cite
|
Sign up to set email alerts
|

The fluorescence properties of aerosol larger than 0.8 μm in urban and tropical rainforest locations

Abstract: Abstract. UV-LIF measurements were performed on ambient aerosol in Manchester, UK (urban city centre, winter) and Borneo, Malaysia (remote, tropical) using a Wide Issue Bioaerosol Spectrometer, version 3 (WIBS3). These sites are taken to represent environments with minor and significant primary biological aerosol (PBA) influences respectively, and the urban dataset describes the fluorescent background aerosol against which PBA must be identified by researchers using LIF. The ensemble aerosol at both sites was … Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

10
107
1

Year Published

2012
2012
2017
2017

Publication Types

Select...
6
2
1

Relationship

1
8

Authors

Journals

citations
Cited by 92 publications
(119 citation statements)
references
References 32 publications
(39 reference statements)
10
107
1
Order By: Relevance
“…New methods employing laser-induced fluorescence to identify and count biological particles (e.g. Gabey et al, 2010Gabey et al, , 2011Huffman et al, 2010) may offer new opportunities to evaluate model predictions. We note that existing PBAP emission schemes have not been designed to adequately represent seasonal and interannual variability.…”
Section: Discussionmentioning
confidence: 99%
“…New methods employing laser-induced fluorescence to identify and count biological particles (e.g. Gabey et al, 2010Gabey et al, , 2011Huffman et al, 2010) may offer new opportunities to evaluate model predictions. We note that existing PBAP emission schemes have not been designed to adequately represent seasonal and interannual variability.…”
Section: Discussionmentioning
confidence: 99%
“…An early generation UV-APS (Ho, 2002) was used for short periods to measure background FBAP concentrations at several military locations within Canada and Sweden (Ho and Spence, 1998;Ho et al, 2004), and a different LIF spectrometer design was utilised for detection of FBAP in ambient air in several US locations Pan et al, 2007;Pan et al, 2009). Recently, fluorescence measurements of biological aerosols have also been reported in more detail for tropical rainforest air (Prenni et al, 2009;Gabey et al, 2010;Po¨schl et al, 2010) as well as in two urban European locations (Huffman et al, 2010;Gabey et al, 2011).…”
Section: Modern Analysis Methodsmentioning
confidence: 99%
“…Here we focus upon development of analysis techniques for the Wideband Integrated Bioaerosol Sensor (WIBS) range of auto-fluorescence detectors (Foot et al, 2008;Gabey et al, 2010Gabey et al, , 2011Kaye et al, 2005). We demonstrate the application of a cluster analysis technique to the WIBS single-particle data, allowing for robust statistical resolution of different PBAP subgroups.…”
Section: N H Robinson Et Al: Cluster Analysis Of Wibs Datamentioning
confidence: 99%