The Flow Field Analysis and Flow Calculation of Ultrasonic Flowmeter Based on the Fluent Software

Abstract: We can build the three-dimensional structure model based on the Gambit software and achieve the distribution of flow field in the pipe and reflux flow condition at the position of transducer in regard to the real position of transducer according to the Fluent software. Under the framework, define the reflux length based on the distance of reflux along the channel and evaluate the effect of reflux on flow field. Then we can correct the power factor with the transmission speed difference method in the ideal cond… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(7 citation statements)
references
References 7 publications
0
5
0
Order By: Relevance
“…It can be seen that the ultrasonic wave travels through the flow with varying local velocities which the transducers measure as a line-average velocity [8]. This average however fails to account for the actual velocity distribution across the pipe cross section which in reality is two dimensional [21]. A flow profile correction factor (FPCF) is needed in order to accurately determine the flow velocity and therefore the mass flow rate.…”
Section: Reynolds Number and Flow Profile Correctionmentioning
confidence: 99%
“…It can be seen that the ultrasonic wave travels through the flow with varying local velocities which the transducers measure as a line-average velocity [8]. This average however fails to account for the actual velocity distribution across the pipe cross section which in reality is two dimensional [21]. A flow profile correction factor (FPCF) is needed in order to accurately determine the flow velocity and therefore the mass flow rate.…”
Section: Reynolds Number and Flow Profile Correctionmentioning
confidence: 99%
“…The measurement principle of the fluid in a pipe in a singlepath ultrasonic flowmeter can be observed from Figure 1 [9]. The figure assumed that the diameter of the pipe is mentioned by D, ultrasonic transducers are installed on A and B sides from the pipe, which could emit and receive the ultrasonic signals, the distance between A and B represents by L, and θ is the angle of AB with the pipe axis.…”
Section: U Ul Lt Tr Ra As So On Ni Ic C F Fl Lo Ow Wm Me Et Te Ermentioning
confidence: 99%
“…The concrete has a good air blocking ability and a strong compression resistance, but the dust generated in the spraying process is large, the coating rebound is large, and the transportation cost of sand, cement, and other materials is high. The fly ash filling technology often needs to arrange boreholes on the side of the roadway, which make the roadway have more cracks after filling, so the effect of blocking the air leakage is not good [11][12][13][14][15][16].…”
Section: Introductionmentioning