2010
DOI: 10.1063/1.3491032
|View full text |Cite
|
Sign up to set email alerts
|

The first measurements of soft x-ray flux from ignition scale Hohlraums at the National Ignition Facility using DANTE (invited)

Abstract: The first 96 and 192 beam vacuum Hohlraum target experiments have been fielded at the National Ignition Facility demonstrating radiation temperatures up to 340 eV and fluxes of 20 TW/sr as viewed by DANTE representing an ∼20 times flux increase over NOVA/Omega scale Hohlraums. The vacuum Hohlraums were irradiated with 2 ns square laser pulses with energies between 150 and 635 kJ. They produced nearly Planckian spectra with about 30±10% more flux than predicted by the preshot radiation hydrodynamic simulations.… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
14
0

Year Published

2011
2011
2021
2021

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 71 publications
(14 citation statements)
references
References 27 publications
(3 reference statements)
0
14
0
Order By: Relevance
“…The NEL drive results in turn matched modeling validated by prior similar energy Nova 31 and OMEGA 32 facility hohlraum data 33 taken with the same type of Dante detector itself shown to agree 34 with the analogous soft x-ray power diagnostic for the LMJ facility, 35 DMX. 36 This x-ray drive consistency across facilities 37 has lent further credence to an observed improvement 38 in x-ray CE at fixed laser intensity as vacuum hohlraum scale is increased on NIF, attributed to increased volume-to-surface area ratio. Finally, gas-filled hohlraums 39,40 and tubes 41 demonstrated the efficacy of laser spot smoothing in improving radiation drive and beam propagation using phase plates, 42 polarization smoothing 43 (PS), and smoothing by spectral dispersion (SSD) for both the cases of a NIF quad geometry and the NIF-like multicone OMEGA geometry.…”
Section: -2mentioning
confidence: 60%
“…The NEL drive results in turn matched modeling validated by prior similar energy Nova 31 and OMEGA 32 facility hohlraum data 33 taken with the same type of Dante detector itself shown to agree 34 with the analogous soft x-ray power diagnostic for the LMJ facility, 35 DMX. 36 This x-ray drive consistency across facilities 37 has lent further credence to an observed improvement 38 in x-ray CE at fixed laser intensity as vacuum hohlraum scale is increased on NIF, attributed to increased volume-to-surface area ratio. Finally, gas-filled hohlraums 39,40 and tubes 41 demonstrated the efficacy of laser spot smoothing in improving radiation drive and beam propagation using phase plates, 42 polarization smoothing 43 (PS), and smoothing by spectral dispersion (SSD) for both the cases of a NIF quad geometry and the NIF-like multicone OMEGA geometry.…”
Section: -2mentioning
confidence: 60%
“…The absolute combined response function of each channel, as well as its uncertainty are known and characterised. This allows for absolute measurements of the X-ray emission which are commonly used by experimentalists to calculate the radiation temperature in ICF related experiments [123,124]. Recently, it was shown that a priori information can be introduced in this analysis to elliminate the assumption of a Planckian radiation field, which produces more accurate results [125].…”
Section: Dantementioning
confidence: 99%
“…Sample temperature in the NIF experiment can be evaluated in two ways. Figure 1 (right) showed the diagnostic view of an absolutely calibrated X-ray flux diagnostic (DANTE-2) [19][20][21][22], which measured an effective brightness temperature of around 140-150 eV during the time of the X-ray transmission measurement (4.3 ns) for the NIF shot discussed in this paper. The X-ray transmission measurement time itself is measured separately, after time-of-flight corrections, from the capsule backlighter's X-ray flash observed using the other flux diagnostic (DANTE-1).…”
Section: Plasma Conditionsmentioning
confidence: 99%