The fabrication and anticorrosive performances of sulfonate‑barium@sulfonated graphene composite filler

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 50 publications
0
4
0
Order By: Relevance
“…0, the electrochemical test impedance is approximately equal to the coating resistance, so the impedance at low frequency can be used as the basis for evaluating the coating resistance, and the impedance measured at f = 0.01 Hz is generally taken to be Z f=0.01 Hz . 17 As can be seen, the Gr02-QA02 showed a low impedance mode value in the low-frequency region from the beginning (at day 0), while the others showed impedance modulus values above 11th power. After 20 days of immersion, the QA05 and Gr02-QA05 showed no significant change in the low-frequency impedance modulus, while others decreased.…”
Section: Electrochemical Analysismentioning
confidence: 82%
See 2 more Smart Citations
“…0, the electrochemical test impedance is approximately equal to the coating resistance, so the impedance at low frequency can be used as the basis for evaluating the coating resistance, and the impedance measured at f = 0.01 Hz is generally taken to be Z f=0.01 Hz . 17 As can be seen, the Gr02-QA02 showed a low impedance mode value in the low-frequency region from the beginning (at day 0), while the others showed impedance modulus values above 11th power. After 20 days of immersion, the QA05 and Gr02-QA05 showed no significant change in the low-frequency impedance modulus, while others decreased.…”
Section: Electrochemical Analysismentioning
confidence: 82%
“…The Bode plots of the EIS results for each group of coatings immersed in 3.5 wt% NaCl solution for 140 days are shown in Figure 14. When the scan frequency f → 0, the electrochemical test impedance is approximately equal to the coating resistance, so the impedance at low frequency can be used as the basis for evaluating the coating resistance, and the impedance measured at f = 0.01 Hz is generally taken to be Z f=0.01 Hz 17 . As can be seen, the Gr02‐QA02 showed a low impedance mode value in the low‐frequency region from the beginning (at day 0), while the others showed impedance modulus values above 11th power.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…In addition to element doping and chemical passivation, insulating material encapsulation is also an effective way to reduce graphene's conductivity. The insulating encapsulation of graphene by nanoparticles such as sulfonate-barium (BS) and ZrO 2 triumphantly restrained the corrosion promotion activity of graphene [28,29]. Whereas the limited compatibility between the graphene encapsulated by inorganic nanoparticles and the polymer is still not ideal for improving the barrier performance of the composite coating [30].…”