The excitation of UHF signals by partial discharges in GIS

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
123
0
1

Year Published

1999
1999
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 326 publications
(130 citation statements)
references
References 13 publications
0
123
0
1
Order By: Relevance
“…Figure 5 shows typical injected current signal generated due to partial discharges generated during tree propagation. It is well established that the rise time and fall time of the injected current pulse formed due to partial discharge signal in the SF 6 insulation medium are of few nanoseconds radiating UHF signals [6]. Figure 6 (i) and (ii) shows typical time domain UHF signal generated due to partial discharge formed owing to tree inception and propagation under AC voltages and the corresponding FFT analysis of the time domain signal respectively.…”
Section: Analysis Of Uhf Signal Generated During Tree Growthmentioning
confidence: 99%
See 1 more Smart Citation
“…Figure 5 shows typical injected current signal generated due to partial discharges generated during tree propagation. It is well established that the rise time and fall time of the injected current pulse formed due to partial discharge signal in the SF 6 insulation medium are of few nanoseconds radiating UHF signals [6]. Figure 6 (i) and (ii) shows typical time domain UHF signal generated due to partial discharge formed owing to tree inception and propagation under AC voltages and the corresponding FFT analysis of the time domain signal respectively.…”
Section: Analysis Of Uhf Signal Generated During Tree Growthmentioning
confidence: 99%
“…These pre-breakdown channels emanated from the defect site in the insulation structure resemble branches of a tree and, hence, the name "treeing" is given to the damage process and since such an occurrence is purely due to electrical stress the mechanism is termed as "Electrical Treeing" [2][3][4][5]. In general, the partial discharge injected current pulses involve rise and fall-times of about 1 ns or less, exciting signals in the UHF range of 300-3000 MHz [6].…”
Section: Introductionmentioning
confidence: 99%
“…3, a series arc occurs at an electrical junction in series with a load and is caused by an incomplete connection as the result of corrosion or vibration. The current flowing is much less than that of a parallel arc, but can causes line-to-ground faults or short circuits by oxidizing and thermally degrading the surrounding insulation materials [11][12][13][14]. …”
Section: Series Arc Dischargementioning
confidence: 99%
“…However, the live diagnosis depending on the classic method, such as existing infrared cameras and leakage current measurement method in the case of ultra high voltage switchgear, is not effective for the prevention of power outage accidents, because the switchgear internal structure is complex, and it is difficult to determine the occurrence of partial discharge [3]. As a live-diagnosis technique of GIS, UHF technology was applied to the switchboard, and the possibility of application studied [4,5]. The technology by using UHF sensors is simply measured, and the interpretation of diagnostic results is an easy technique, as waveform analysis is standardized by the result of numerous studies.…”
Section: Department Of Car Mechatronics Sahmyook University Seoul 1mentioning
confidence: 99%