2018
DOI: 10.1016/j.apgeochem.2018.01.008
|View full text |Cite
|
Sign up to set email alerts
|

The European Shale: An improved data set for normalisation of rare earth element and yttrium concentrations in environmental and biological samples from Europe

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
50
0
1

Year Published

2019
2019
2023
2023

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 106 publications
(73 citation statements)
references
References 24 publications
2
50
0
1
Order By: Relevance
“…The powders were acid-digested according to the protocol of Kraemer et al (2019) with a mixture of suprapure HF-HClO 4 in a Picotrace DAS digestion unit and analyzed with a Perkin-Elmer Nexion 350x ICP-MS at the Geochemistry Laboratory of Jacobs University Bremen. REY concentrations are normalized to European Shale (EUS) of Bau et al (2018). Normalized data is indicated with the subscript SN (shalenormalized).…”
Section: Solution Icp-msmentioning
confidence: 99%
“…The powders were acid-digested according to the protocol of Kraemer et al (2019) with a mixture of suprapure HF-HClO 4 in a Picotrace DAS digestion unit and analyzed with a Perkin-Elmer Nexion 350x ICP-MS at the Geochemistry Laboratory of Jacobs University Bremen. REY concentrations are normalized to European Shale (EUS) of Bau et al (2018). Normalized data is indicated with the subscript SN (shalenormalized).…”
Section: Solution Icp-msmentioning
confidence: 99%
“…There is a variation in major and trace element concentrations of > 15% between the duplicates/triplicates of most samples. This variability is surprisingly high and has not been encountered in our laboratory in studies of other materials 39,55,56 . Nevertheless, in order to exclude analytical error, selected samples were re-measured on an Elan DRCe ICP-MS, i.e.…”
Section: Methodsmentioning
confidence: 78%
“…The accuracy and precision of the analytical methodology for elemental determinations were assessed by replicate analysis of certified reference material BCR-146. The normalization was done according to Loring and Rantala (1992) through the ratio of the reference metal Aluminum and the element Yttrium (Turekian and Wedepohl, 1961;Prokisch et al, 2000;Bau et al, 2018). Blanks and the concurrent analysis of the standard reference material were used to detect possible contamination/losses during analysis.…”
Section: Element Analysismentioning
confidence: 99%