2015
DOI: 10.1186/s40201-015-0174-2
|View full text |Cite
|
Sign up to set email alerts
|

The estimation of per capita loadings of domestic wastewater in Tehran

Abstract: The amount of wastewater characteristics loading is one of the main parameters in the design of wastewater collection and treatment systems. The generation per capita per day (GPCD) of wastewater characteristics was estimated by analyzing the monthly data of nine wastewater treatment plants in Tehran, capital city of Iran. GPCD values were calculated from measured collected wastewater flow, the population and concentration data. The results indicated the values of 32.96 ± 1.91, 49.25 ± 2.49, 37.31 ± 2.44, 6.77… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 27 publications
(7 citation statements)
references
References 10 publications
0
7
0
Order By: Relevance
“…The lowest discharges were observed during the early morning time (1:00 -7:00). Unit pollution loads of SS, VSS, COD Cr , BOD 5 [16], Brazil, Denmark, Japan [3]. This remarkable difference might be explained by the difference in living situation among the countries, but also might be due to in-sewer processes such as sewer leakage, the particle settling due to low velocity in study area.…”
Section: At Wastewater Treatment Plants (Influent)mentioning
confidence: 99%
“…The lowest discharges were observed during the early morning time (1:00 -7:00). Unit pollution loads of SS, VSS, COD Cr , BOD 5 [16], Brazil, Denmark, Japan [3]. This remarkable difference might be explained by the difference in living situation among the countries, but also might be due to in-sewer processes such as sewer leakage, the particle settling due to low velocity in study area.…”
Section: At Wastewater Treatment Plants (Influent)mentioning
confidence: 99%
“…Based on UNEP (2000) and Mesdaghinia et al (2015) a TDS emission factor of 100 g/cap/day was assigned to all three continents.…”
Section: Region Regional Average [Cfu*/cap/year] Referencementioning
confidence: 99%
“…Some of the strengths of this software include high flexibility, low error rate, and careful financial sensitivity analysis [21]. According to Mesdaghinia et al [22], the per capita sludge produced from Tehran wastewater is between 0.16 ± 0.02 and 0.11 ± 0.02 L per day. If this amount is considered for Iran, for a population of about 82.35 million people, 5410.7 million liters' sewage sludge will be obtained from Iranian municipal sewage annually.…”
Section: Techno-economic Assessmentmentioning
confidence: 99%