IEEE 1999 International Geoscience and Remote Sensing Symposium. IGARSS'99 (Cat. No.99CH36293)
DOI: 10.1109/igarss.1999.774658
|View full text |Cite
|
Sign up to set email alerts
|

The Envisat-1 Advanced Synthetic Aperture Radar instrument

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(6 citation statements)
references
References 1 publication
0
6
0
Order By: Relevance
“…Previous studies have been focusing more on the calibration of cross‐talk contamination on quad or dual polarization data [ van Zyl , ; Dubois et al ., ; Freeman et al ., ; Touzi and Shimada , ]. The consensus is that cross‐talk level can be suppressed down to −30 dB after full polarimetric calibration [ Touzi et al ., ] and −35 dB for dual polarization calibration [ Shimada et al ., ; Suchail et al ., ; Uher et al ., ; Miller et al ., ]. There have been very few studies focusing on the actual impact of polarimetric channel cross‐talk contamination on end applications of polarimetric synthetic aperture radar (SAR).…”
Section: Introductionmentioning
confidence: 98%
“…Previous studies have been focusing more on the calibration of cross‐talk contamination on quad or dual polarization data [ van Zyl , ; Dubois et al ., ; Freeman et al ., ; Touzi and Shimada , ]. The consensus is that cross‐talk level can be suppressed down to −30 dB after full polarimetric calibration [ Touzi et al ., ] and −35 dB for dual polarization calibration [ Shimada et al ., ; Suchail et al ., ; Uher et al ., ; Miller et al ., ]. There have been very few studies focusing on the actual impact of polarimetric channel cross‐talk contamination on end applications of polarimetric synthetic aperture radar (SAR).…”
Section: Introductionmentioning
confidence: 98%
“…The miscalibration parameters in first three rows of the tables are chosen according to the actual antenna performance of several PolSAR systems [15][16][17][18][19][20], and 'Total' represents the pixels of the whole image, 'Surface', 'Double' and 'Volume' represent, respectively, the pixels classified into surface, double or multiple and volume-scattering types by the real data.…”
Section: Effect On the Classification Based On Eigenvector/eigenvaluementioning
confidence: 99%
“…A small cut (20 pixels) was made to show profiles of the effect of miscalibration on the polarimetric parameters. According to the optimal calibration performance of several PolSAR systems [15–20], the amplitude and phase of f are set to be 0.5 dB and 5̂°, respectively, and the parameter δ equals to −35 dB. In all the graphs displayed in Figs.…”
Section: Effect Of Miscalibration On Polarimetric Parametersmentioning
confidence: 99%
See 1 more Smart Citation
“…ASAR wide swath mode is a five-swath ScanSAR, and the echo data of the fourth subswath is used in our experiments. The basic parameters [8][9][10] are shown in Tab.1.…”
Section: Experimental Settingsmentioning
confidence: 99%