Our system is currently under heavy load due to increased usage. We're actively working on upgrades to improve performance. Thank you for your patience.
2019
DOI: 10.1016/j.apenergy.2019.04.026
|View full text |Cite
|
Sign up to set email alerts
|

The environment and energy consumption of a subway tunnel by the influence of piston wind

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
9
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 62 publications
(11 citation statements)
references
References 22 publications
0
9
0
Order By: Relevance
“…(CO2), volatile organic compounds, odors and particulates. In UMSs, indoor CO2 [35] and particulate matters (PMs) concentration [5,36] are major environmental parameters linked with IAQ:…”
Section: Iaq Inside Metro Stationsmentioning
confidence: 99%
See 1 more Smart Citation
“…(CO2), volatile organic compounds, odors and particulates. In UMSs, indoor CO2 [35] and particulate matters (PMs) concentration [5,36] are major environmental parameters linked with IAQ:…”
Section: Iaq Inside Metro Stationsmentioning
confidence: 99%
“…Due to the complexity of the environment of UMSs, various systems have been developed to suit different function requirements. These systems can generally be classified into 1) public areas HVAC system [40,41], 2) under platform exhaust (UPE) system [42], and 3) tunnel ventilation system [43,44].…”
Section: Hvac Systems In Umssmentioning
confidence: 99%
“…Ma et al [31] developed a one-dimensional model using the IDA Simulation Environment based on an actual metro line and tested the wind velocity in the actual tunnel to validate the results. Liu et al [32] created a 1/16 scaled subway tunnel model to develop and validate a three-dimensional computational model. Krasyuk et al [33] carried out a field measurement of piston wind in an actual subway and refined the network calculation model based on the measured results.…”
Section: Introductionmentioning
confidence: 99%
“…So it is of great importance to conduct the research on the piston effect on the airflow and thermal environment in the station. In subway station, relative research have been conducted widely by researchers in previous published papers [10][11][12][13]. For example, Wang et al conducted the experimental study on particulate matter (PM) concentrations in Shanghai subway system and found that piston wind would influence the pollutant distribution in the station [11].…”
Section: Introductionmentioning
confidence: 99%
“…For example, Wang et al conducted the experimental study on particulate matter (PM) concentrations in Shanghai subway system and found that piston wind would influence the pollutant distribution in the station [11]. Liu et al focused on CO2 concentration and thermal environment in subway system and analyzed the energy consumption when the piston wind is utilized fully [12]. Due to the potential of the E3S Web of Conferences 165, 04075 (2020) https://doi.org/10.1051/e3sconf/202016504075 CAES 2020 piston wind in energy saving, vented platform screen doors are investigated widely in recent years.…”
Section: Introductionmentioning
confidence: 99%