The energy dependence and dose response of a commercial optically stimulated luminescent detector for kilovoltage photon, megavoltage photon, and electron, proton, and carbon beams

Abstract: Optically stimulated luminescent detectors, which are widely used in radiation protection, offer a number of potential advantages for application in radiation therapy dosimetry. Their introduction into this field has been somewhat hampered by the lack of information on their radiation response in megavoltage beams. Here the response of a commercially available optically stimulated luminescent detector (OSLD) is determined as a function of energy, absorbed dose to water, and linear energy transfer (LET). The de… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

9
164
3
1

Year Published

2011
2011
2020
2020

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 172 publications
(177 citation statements)
references
References 23 publications
9
164
3
1
Order By: Relevance
“…Measurements were not converted to absolute dose considering the other correction factors that have inherent uncertainties; e.g., energy dependence, absolute reader sensitivity, etc. [12][13][14][15] Inclusion of this would introduce unnecessary uncertainty that this study did not attempt to address; however, a facility using an OSL system would need to characterize these basic factors to reduce uncertainty in converting the OSLD measurement to an absorbed dose.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…Measurements were not converted to absolute dose considering the other correction factors that have inherent uncertainties; e.g., energy dependence, absolute reader sensitivity, etc. [12][13][14][15] Inclusion of this would introduce unnecessary uncertainty that this study did not attempt to address; however, a facility using an OSL system would need to characterize these basic factors to reduce uncertainty in converting the OSLD measurement to an absorbed dose.…”
Section: Discussionmentioning
confidence: 99%
“…15 Sensitivity of the dosimeter has been shown not to change significantly at cumulative doses below 10 Gy. 11,12,19 Even so, the experiments were performed in such a way as to keep the cumulative dose as even as possible amongst the dosimeters to eliminate such uncertainties. No dosimeter received a cumulative dose over 10 Gy.…”
Section: Iia Dosimeter and Readout Systemmentioning
confidence: 99%
See 2 more Smart Citations
“…For instance, the EPM for a Landauer OSL was determined by Zhuang and Olch (11) to be DOSL=0.8 mm, and 0.07 cm 2 /gm by Reft (31) . The thickness of TLD100 was 0.38 mm (ρ=2.64 normalg/cm3); therefore, with the assumption that the EPM is located at the midpoint of the TLD, then DTLD=0.5 mm of water.…”
Section: Discussionmentioning
confidence: 99%