2021
DOI: 10.3390/ma14216388
|View full text |Cite
|
Sign up to set email alerts
|

The Electrospray (ESI) and Flowing Atmosphere-Pressure Afterglow (FAPA) Mass Spectrometry Studies of Nitrophenols (Plant Growth Stimulants) Removed Using Strong Base-Functionalized Materials

Abstract: The functional silica-based materials functionalized with a strong nitrogen base TBD (SiO2-TBD) deposited via a linker or with a basic poly(amidoamine) dendrimer containing multiple terminal amine groups -NH2 (SiO2-EDA) and functional polymers containing a strong phosphazene base (Polymer-Phosphazene) or another basic poly(amidoamine) dendrimer (PMVEAMA-PAMAM) were tested as sorbents dedicated to a mixture of nitrophenols (p-nitrophenol and 2-methoxy-5-nitrophenol), which are analogs of nitrophenols used in pl… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 31 publications
0
2
0
Order By: Relevance
“…D FA 1000 n the en capilla ature was chain and observed s allowed nately, the were not we were ower temn [24]. We pt away in rapid desn gas temto observe rk we will hromatogt leads to ion source n our labinvolving sitive and on a Xevo the Glow laboratory ption [24], per would good smaompounds ctrometer [26]). The ecules and ve plasma or molecrce will be ential for d be easily d ambient a range of on a XeY spectromcation lies into the…”
Section: Introductionmentioning
confidence: 92%
See 1 more Smart Citation
“…D FA 1000 n the en capilla ature was chain and observed s allowed nately, the were not we were ower temn [24]. We pt away in rapid desn gas temto observe rk we will hromatogt leads to ion source n our labinvolving sitive and on a Xevo the Glow laboratory ption [24], per would good smaompounds ctrometer [26]). The ecules and ve plasma or molecrce will be ential for d be easily d ambient a range of on a XeY spectromcation lies into the…”
Section: Introductionmentioning
confidence: 92%
“…In answer to the question posed: it is most likely fiction to assume that a single source may achieve this goal. However, a multimodal solution may be the answer and several researchers have investigated combing two or more sources to broaden the types of analytes that can be ionised in a single analysis [24,25,26] suggesting a possible solution.…”
Section: Characteristicmentioning
confidence: 99%