2001
DOI: 10.1016/s0361-9230(01)00585-8
|View full text |Cite
|
Sign up to set email alerts
|

The electroretinogram and visual evoked potential of freely moving rats

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
36
0

Year Published

2005
2005
2020
2020

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 29 publications
(36 citation statements)
references
References 25 publications
0
36
0
Order By: Relevance
“…In our previous studies with rats (Galambos et al, 2000Szabo-Salfay et al, 2001) the retina was illuminated from behind by LEDs glued to the skull. We undertook to simulate that unusual stimulus path in these human studies by delivering the stimuli through the closed eyelid.…”
Section: Experiments 4 Eye Closed Controlmentioning
confidence: 99%
See 1 more Smart Citation
“…In our previous studies with rats (Galambos et al, 2000Szabo-Salfay et al, 2001) the retina was illuminated from behind by LEDs glued to the skull. We undertook to simulate that unusual stimulus path in these human studies by delivering the stimuli through the closed eyelid.…”
Section: Experiments 4 Eye Closed Controlmentioning
confidence: 99%
“…It briefly summarizes previous results obtained from the Wistar rat, our model of the mammalian visual system (Galambos et al, 2000Szabo-Salfay et al, 2001). Two small LEDs glued to the rat's skull deliver red stimuli on command (continuous, intermittent, or both) as the animal sleeps or moves about in darkness within a small box.…”
Section: Introductionmentioning
confidence: 97%
“…corneal ERGs from anaesthetized rats [4]; corneal and scleral ERGs by chronic implants from non-anaesthetized rats [53]), the SC (e.g. [9,30]), and the primary visual cortex (e.g.…”
Section: Discussionmentioning
confidence: 99%
“…Neuromuscular blockers and anaesthetic agents are used in ERG experimentation to achieve an unconscious and motionless state. There have only been five reports of awake ERG recordings in rats [16][17][18][19][20] . In these studies, electrodes were surgically pre-implanted into the skull and two of these studies tested the effect of anaesthesia on the ERG 17,20 .…”
Section: Anesthesiamentioning
confidence: 99%
“…Set the band pass filters to 1-1,000 Hz and ensure that sampling is triggered to sample the period of ~250 msec following a flash. 16 . An ERG waveform similar to Figure 2A should appear.…”
Section: Introductionmentioning
confidence: 99%