2001
DOI: 10.1016/s0168-9002(01)00646-5
|View full text |Cite
|
Sign up to set email alerts
|

The electronics and data acquisition systems of a CsI(Tl) scintillating crystal detector for low energy neutrino experiment

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
13
0

Year Published

2002
2002
2020
2020

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 27 publications
(14 citation statements)
references
References 4 publications
1
13
0
Order By: Relevance
“…The fraction DT/(1-DT) is the ratio of recorded double-α events in DS 3a where the third one is missing to the triple-α events where the entire sequence DS 3a and DS 3b are reconstructed. The measured value is DT=9±1%, in good agreement to DT=9.5% derived by an alternative method using random trigger events [3].…”
Section: Data Acquisition Dead Timesupporting
confidence: 85%
See 1 more Smart Citation
“…The fraction DT/(1-DT) is the ratio of recorded double-α events in DS 3a where the third one is missing to the triple-α events where the entire sequence DS 3a and DS 3b are reconstructed. The measured value is DT=9±1%, in good agreement to DT=9.5% derived by an alternative method using random trigger events [3].…”
Section: Data Acquisition Dead Timesupporting
confidence: 85%
“…The detectors are read out by a versatile electronics and data acquisition (DAQ) system [3] based on 16-channel, 20 MHz, 8-bit Flash Analog-to-Digital-Convertor (FADC) modules. The readout allows full recording of all the relevant pulse shape and timing information for as long as 500 µs after the initial trigger with a resolution of 1 µs.…”
Section: Introductionmentioning
confidence: 99%
“…The inner shieldings and detectors were covered by a plastic bag connected to the exhaust line of the dewar, serving as a purge for the radioactive radon gas. The electronics and data acquisition (DAQ) system [36] of the HPGe detector assembly is illustrated schematically in Figure 8. The HPGe pre-amplifier signals were distributed to two spectroscopy amplifiers at the same 4 µs shaping time but with different gain factors.…”
Section: Experimental Set-upmentioning
confidence: 99%
“…Descriptions of the experimental hardware and analysis procedures were presented in details in Refs. [15]& [16]. The primary scientific goal was the search of neutrino magnetic moments.…”
Section: Axion Detection and Experimental Setupmentioning
confidence: 99%