The efficiency of an air filtration system in the hospital ward

Abstract: A study was conducted to ascertain the efficiency and effectiveness of an air filtration system (Electromedia Model 100C, Clean Air UK, UK) in the hospital ward. The sampling was conducted using a portable Surface Air Sampler (Cherwell Laboratories, Bicester, UK) in conjunction with settle plates. Samples were taken two days before and two days following activation of the filtration system and results compared. A clear, demonstrable, statistically significant reduction in microbial organisms following the acti… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2008
2008
2021
2021

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(2 citation statements)
references
References 16 publications
0
2
0
Order By: Relevance
“…The complex inpatient cancer center environment demands special consideration to ensure a healthy indoor air quality to protect patients against hospital-acquired infections [19,20]. Sources of air pollution within the hospital include chemicals and microbial air pollutants from various sources [21]. Properly designed systems and optimal operations are essential to control and mitigate potential sources of pollutants such as air filtration, differential pressure control, directional airflow control, and ultraviolet germicidal irradiation disinfection, among others [22].…”
Section: Environmentalmentioning
confidence: 99%
“…The complex inpatient cancer center environment demands special consideration to ensure a healthy indoor air quality to protect patients against hospital-acquired infections [19,20]. Sources of air pollution within the hospital include chemicals and microbial air pollutants from various sources [21]. Properly designed systems and optimal operations are essential to control and mitigate potential sources of pollutants such as air filtration, differential pressure control, directional airflow control, and ultraviolet germicidal irradiation disinfection, among others [22].…”
Section: Environmentalmentioning
confidence: 99%
“…Increase of airborne biological particles concentration in buildings could be due to microbial release from contaminated moist materials like walls, carpet or curtains but the main part of indoor bioaerosols come from outdoor. In consequence, the ventilation system is the major way to control indoor concentration because its filter retains the main part of microorganisms flow from the outside (Möritz et al, 2001;McLarnon et al, 2006) with an efficiency close to non-biological particle efficiency (Maus and Umhauer, 1997). Both biological and non-biological particles accumulate onto the filtering media.…”
Section: Introductionmentioning
confidence: 99%