2017
DOI: 10.1063/1.4996019
|View full text |Cite
|
Sign up to set email alerts
|

The effects of the cathode array on emitted hard x-ray from a small plasma focus device

Abstract: In this study, the effects of the cathode array variations on emitted hard x-rays from a small Mather type plasma focus device (450 J) were investigated. The gradual elimination of the cathode rods inside the cathode array of the device lowered the quality and quantity of the emitted hard x-rays at different pressure values of argon gas. We theorized that the variations of the cathode array were able to change some discharge parameters that could vary the number of the energetic runaway electrons generated dur… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 29 publications
0
3
0
Order By: Relevance
“…For both sensors, the wavelet transform representation is also included for visualizing the frequency components that appear during the discharge. The use of the wavelet transform is adequate given that one of its applications is for detecting time-localized events in noisy signals [51] and, previously, it was used by Piriaei et al [52] for analyzing the frequency content of electric signals measured from the DPF operation using a Mirnov coil.…”
Section: A Time and Frequency Domain Analysis Of The Measured Signalsmentioning
confidence: 99%
“…For both sensors, the wavelet transform representation is also included for visualizing the frequency components that appear during the discharge. The use of the wavelet transform is adequate given that one of its applications is for detecting time-localized events in noisy signals [51] and, previously, it was used by Piriaei et al [52] for analyzing the frequency content of electric signals measured from the DPF operation using a Mirnov coil.…”
Section: A Time and Frequency Domain Analysis Of The Measured Signalsmentioning
confidence: 99%
“…Piriaei et al [28][29][30] reports an experiment where three types of cathodes were examined. Like part of the results, the experience shows a noticeable decrease in the x-ray production when a structure cathode-less is used.…”
Section: Introductionmentioning
confidence: 99%
“…Except for the papers of Gerdin et al [34] and Schmidt et al [33], no further relationship of the EM radiation with plasma focus phenomena has been reported. Using a Mirnov Coil, an inductive sensor, Piriaei et al [35] associated a relation between the measured signal and changes in the electrode geometry of a plasma focus device.…”
Section: Introductionmentioning
confidence: 99%