2020
DOI: 10.1016/j.engstruct.2019.110149
|View full text |Cite
|
Sign up to set email alerts
|

The effects of steel X-brace retrofitting of RC frames on the seismic performance of frames and their elements

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
22
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 41 publications
(23 citation statements)
references
References 24 publications
1
22
0
Order By: Relevance
“…in the study, the two cases are analyzed where the in case I, the inverted V bracings are used such a that it only applied in the incomplete ways or only added the bracings in a single axis of the structures and in case II the bracings are applied in both the directions as shown in Table 3. In both cases, the design base shear is observed in both directions as shown in Fig 3 . It is observed that adding the steel bracings increases the base shear values of the structure and similar results also observed in [28], [31]. In model L3, the bracings are added in such a way that it resist the lateral load along the yaxis.…”
Section: Design Base Shear Variationssupporting
confidence: 84%
See 3 more Smart Citations
“…in the study, the two cases are analyzed where the in case I, the inverted V bracings are used such a that it only applied in the incomplete ways or only added the bracings in a single axis of the structures and in case II the bracings are applied in both the directions as shown in Table 3. In both cases, the design base shear is observed in both directions as shown in Fig 3 . It is observed that adding the steel bracings increases the base shear values of the structure and similar results also observed in [28], [31]. In model L3, the bracings are added in such a way that it resist the lateral load along the yaxis.…”
Section: Design Base Shear Variationssupporting
confidence: 84%
“…The re-entrant corner behavior amplified the displacement along the x-axis [17]. It is noticed that in the case II (L9-L12) models, the steel bracings effectively reduced the maximum displacements [31] as shown in Fig. 5 and 6.…”
Section: Maximum Displacements Responsementioning
confidence: 85%
See 2 more Smart Citations
“…To effectively strengthen structures, the proper retrofitting method must be selected by evaluating the structure's seismic response before and after retrofit [21][22][23][24][25][26][27][28]. Among retrofitting methods, the insertion of shear walls in existing structures is practical and economical, and efficiently increases structure stiffness while decreasing deformation demand.…”
Section: Introductionmentioning
confidence: 99%