2021
DOI: 10.1016/j.bioelechem.2021.107824
|View full text |Cite
|
Sign up to set email alerts
|

The effects of Methanococcus maripaludis on the corrosion behavior of EH40 steel in seawater

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 19 publications
(3 citation statements)
references
References 39 publications
0
3
0
Order By: Relevance
“…Moreover, R ct values decreased rapidly at 4 and 5 d due to the breach of a protective layer, which was consistent with the Nyquist plots. After a 1-day immersion, the radii of capacitive loops in the PASP + GLU group were much larger than those in other groups, suggesting the improved corrosion inhibition in the presence of PASP + GLU . The radii reached their maximum at 3 d and then decreased at 4 and 5 d, which was attributed to the breach of the protective layer .…”
Section: Resultsmentioning
confidence: 89%
See 1 more Smart Citation
“…Moreover, R ct values decreased rapidly at 4 and 5 d due to the breach of a protective layer, which was consistent with the Nyquist plots. After a 1-day immersion, the radii of capacitive loops in the PASP + GLU group were much larger than those in other groups, suggesting the improved corrosion inhibition in the presence of PASP + GLU . The radii reached their maximum at 3 d and then decreased at 4 and 5 d, which was attributed to the breach of the protective layer .…”
Section: Resultsmentioning
confidence: 89%
“…After a 1-day immersion, the radii of capacitive loops in the PASP + GLU group were much larger than those in other groups, suggesting the improved corrosion inhibition in the presence of PASP + GLU. 37 The radii reached their maximum at 3 d and then decreased at 4 and 5 d, which was attributed to the breach of the protective layer. 38 It is worth noting that a smaller radius was detected in the PASP + GLU group than that in the PASP group at 2 h, indicating that less PASP was attached to the coupon surface in the presence of GLU.…”
Section: Resultsmentioning
confidence: 95%
“…Figure 5a 5) indicated that time constants such as protective film formation and charge-transfer process should be presented, 34 and there are at least two similar relaxation times of time constants during the corrosion of A3 carbon steel. 35,36 As shown in Figure 5a−c, the semicircle diameter in the Nyquist plots was significantly larger than that without s-EPS (Figure 5a), indicating that the charge-transfer resistance and corrosion inhibition rate were increased with s-EPS. 17 Additionally, by a comparation with Figure 5a′, the increased peak heights of Bode plots in Figure 5b′,c′ indicated that protective films were formed with the addition of s-EPS, 33 leading to corrosion inhibition of A3 carbon steel in circulating cooling water.…”
Section: Evaluation Of S-eps Anticorrosion Performance the Corrosion ...mentioning