DOI: 10.1109/11.142666
|View full text |Cite
|
Sign up to set email alerts
|

The effects of electromagnetic fields on cardiac pacemakers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

1996
1996
2024
2024

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 17 publications
(7 citation statements)
references
References 1 publication
0
6
0
Order By: Relevance
“…Some authors contend that pacemakers are extremely resistant to any sort of electromagnetic interference (EMI) found in a hospital and that the only sources of concern should be defibrillators and possibly arc welding (Grant 1993). Others say that pacemakers are shielded from frequencies above 1 kHz and that only ultra high frequencies, 300 MHz-3 GHz, can affect them (Smith and Aasen 1992). It is stated that cardiac pacemaker programming could be affected by EMI, but only if the magnitude of the electric field strength exceeds 200 V m −1 or the magnetic field strength exceeds 10 Gauss (Smith and Aasen 1992).…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Some authors contend that pacemakers are extremely resistant to any sort of electromagnetic interference (EMI) found in a hospital and that the only sources of concern should be defibrillators and possibly arc welding (Grant 1993). Others say that pacemakers are shielded from frequencies above 1 kHz and that only ultra high frequencies, 300 MHz-3 GHz, can affect them (Smith and Aasen 1992). It is stated that cardiac pacemaker programming could be affected by EMI, but only if the magnitude of the electric field strength exceeds 200 V m −1 or the magnetic field strength exceeds 10 Gauss (Smith and Aasen 1992).…”
Section: Discussionmentioning
confidence: 99%
“…Others say that pacemakers are shielded from frequencies above 1 kHz and that only ultra high frequencies, 300 MHz-3 GHz, can affect them (Smith and Aasen 1992). It is stated that cardiac pacemaker programming could be affected by EMI, but only if the magnitude of the electric field strength exceeds 200 V m −1 or the magnetic field strength exceeds 10 Gauss (Smith and Aasen 1992).…”
Section: Discussionmentioning
confidence: 99%
“…Articulography devices are safe for health, complying with various standards regarding exposure to magnetic fields [ 23 ]. However, there are certain considerations with regard to patients who have implanted devices such as pacemakers [ 24 ], cochlear implants [ 25 ], or insulin pumps [ 26 ] because the electromagnetic field can affect their correct operation. Some studies warn about exposure for pregnant women due to the effects of the electromagnetic field not being clear, which is why it is preferable to avoid risks [ 27 ].…”
Section: Methodsmentioning
confidence: 99%
“…Pacemaker is a small, battery-operated electronic biomedical device that capable to normalize the human heartbeats when its natural regulating mechanisms break down [2]. It provides electric impulses that mimic the natural human heartbeats.…”
Section: Pacemakermentioning
confidence: 99%