The Effect of Shank-Space on the Thermal Performance of Shallow Vertical U-Tube Ground Heat Exchangers

Abstract: One parameter that may affect the performance of a ground source heat pump is the shank-space, the center-to-center distance between the two branches of a vertical U-tube used in a ground heat exchanger. A 3D steady-state computational fluid dynamics (CFD) model of a U-tube ground heat exchanger was used to investigate the influence of varying shank-space on the thermal performance of two isolated vertical shallow U-tubes, one 20 m deep and the other 40 m deep, given that most existing research focuses on syst… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 14 publications
(8 citation statements)
references
References 33 publications
0
8
0
Order By: Relevance
“…The model of the BHE lower section was simplified by eliminating the U-junction at the bottom of the U-loop. It is well-known that the removal of a U-shaped connector has no considerable effect on the obtained results and that it significantly reduces the computational cost [38]. Various values for the shank spacing were selected, ranging from 65 mm to 105 mm.…”
Section: Methodsmentioning
confidence: 99%
“…The model of the BHE lower section was simplified by eliminating the U-junction at the bottom of the U-loop. It is well-known that the removal of a U-shaped connector has no considerable effect on the obtained results and that it significantly reduces the computational cost [38]. Various values for the shank spacing were selected, ranging from 65 mm to 105 mm.…”
Section: Methodsmentioning
confidence: 99%
“…Therefore, it is crucial to perform an optimal design of the heat exchange between the fluid and the ground. This topic was analyzed by Vella et al [157], presenting a study for the performance improvement of a ground-source heat pump. They focused on the effect of the distance between the two vertical U-tubes applied in a counter-flow heat exchanger.…”
Section: Buiding Energy Savingmentioning
confidence: 99%
“…Real measurement results are required for calculations and simulations. A number of studies [25][26][27][28][29][30][31][32][33][34] have been conducted to evaluate the performance of BHE in heat pump systems. All of these studies described the impact of BHE based on the evaluation of COP improvement in these systems.…”
Section: Introductionmentioning