1992
DOI: 10.1097/00003086-199202000-00031
|View full text |Cite
|
Sign up to set email alerts
|

The Effect of Patellar Button Placement and Femoral Component Design on Patellar Tracking in Total Knee Arthroplasty

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

5
52
1
1

Year Published

1995
1995
2024
2024

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 112 publications
(59 citation statements)
references
References 0 publications
5
52
1
1
Order By: Relevance
“…The preresection thickness of the patella was measured in all cases and the patellar resection performed with a specialized cutting jig designed to create a composite thickness of the patellar component and the remaining patellar bone that duplicated the native patella thickness. All patella components were positioned to reproduce the position of the native patella high point as described by Yoshii et al [33] whenever possible.…”
Section: Methodsmentioning
confidence: 99%
“…The preresection thickness of the patella was measured in all cases and the patellar resection performed with a specialized cutting jig designed to create a composite thickness of the patellar component and the remaining patellar bone that duplicated the native patella thickness. All patella components were positioned to reproduce the position of the native patella high point as described by Yoshii et al [33] whenever possible.…”
Section: Methodsmentioning
confidence: 99%
“…The patella was resurfaced in all cases with an inset patellar component centered on the median ridge [20]. The patella was cut freehand; and the edges of the resection were sloped, effectively removing osteophytes.…”
Section: Methodsmentioning
confidence: 99%
“…In addition, it is now established that a more anatomic trochlear design can reduce patellofemoral complications [29]. These design changes include lateral orientation of the trochlear groove, a prolonged and deepened intercondylar notch, and high lateral flange [17,[30][31][32][33]. The high lateral flange and deep constrained groove theoretically provide centralizing forces to contain the patella.…”
Section: Biomechanicsmentioning
confidence: 99%
“…Once an equalized surface is created, the patellar-sizing template is placed on the freshly cut surface. The goal is to place the trial as medial as possible without overhanging [15,31,50]. In addition, superior placement of the patellar component minimizes patellar clunk and catching in the inter-condylar region [50].…”
Section: Operative Technique For Resurfacing the Patellamentioning
confidence: 99%