1987
DOI: 10.1063/1.452959
|View full text |Cite
|
Sign up to set email alerts
|

The effect of molecular vibrations on calculated second virial coefficients

Abstract: The limitation of the rigid molecule approximation in the calculation of the second virial coefficient is examined using two different potential models for steam. Both the MCY and the ST2 potentials have been augmented by allowing bond flex and stretch according to an ab initio internal potential. Second virial coefficients are calculated within the classical approximation by the Monte Carlo method. The calculated coefficients with flexible molecules are lower than in the rigid case by up to 10% for the MCY po… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
13
1

Year Published

1989
1989
2009
2009

Publication Types

Select...
3
2
1

Relationship

0
6

Authors

Journals

citations
Cited by 25 publications
(15 citation statements)
references
References 9 publications
1
13
1
Order By: Relevance
“…The Metropolis scheme was then used to either accept or reject the move. The results obtained using this scheme agreed with those using the scheme of Refson et al [2]. However, we found in general that the result converged somewhat faster, usually in between 5 and 7 million steps.…”
Section: Methodssupporting
confidence: 88%
See 3 more Smart Citations
“…The Metropolis scheme was then used to either accept or reject the move. The results obtained using this scheme agreed with those using the scheme of Refson et al [2]. However, we found in general that the result converged somewhat faster, usually in between 5 and 7 million steps.…”
Section: Methodssupporting
confidence: 88%
“…We found it rather puzzling that Refson (0.5-2) x 10 6 configurations, because the model we have used appears simpler than that used in [2]. However, we were demanding a higher accuracy than the 0.5% achieved in [2], since the contributions to B due to vibrations themselves are of a similar order of magnitude in our models, whereas they were larger in [2] (see section 4). It is also possible that for a harmonic potential, convergence is slower.…”
Section: Methodsmentioning
confidence: 50%
See 2 more Smart Citations
“…The quality of the MCY two-body potential was tested by computing various properties of liquid water in Monte Carlo [ 41 and molecular dynamics [ 5,6] simulations; other tests, such as the calculation of the second [ 7,8] and third [ 91 virial coefficients have also been made for the gas state.…”
mentioning
confidence: 99%