2020
DOI: 10.1016/j.jor.2020.06.009
|View full text |Cite
|
Sign up to set email alerts
|

The effect of implant size difference on patient outcomes and failure after bilateral simultaneous total knee arthroplasty

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(3 citation statements)
references
References 26 publications
0
3
0
Order By: Relevance
“…[21][22][23] In the literature, implant size overestimation is not common, and several studies discuss a tendency to underestimate the tibial implant size to reduce soft tissue impingement due to implant overhang. 18,[23][24][25] One study in patients undergoing simultaneous bilateral TKA found an increased risk for aseptic loosening when the tibial component sizes were asymmetric, suggesting the importance of proper sizing in implant longevity. 26 In recent years, vendors have continued to increase the number of available component sizes for TKA.…”
Section: Discussionmentioning
confidence: 99%
“…[21][22][23] In the literature, implant size overestimation is not common, and several studies discuss a tendency to underestimate the tibial implant size to reduce soft tissue impingement due to implant overhang. 18,[23][24][25] One study in patients undergoing simultaneous bilateral TKA found an increased risk for aseptic loosening when the tibial component sizes were asymmetric, suggesting the importance of proper sizing in implant longevity. 26 In recent years, vendors have continued to increase the number of available component sizes for TKA.…”
Section: Discussionmentioning
confidence: 99%
“…The appropriate size of the femoral and tibial components is essential for achieving an acceptable alignment and correct lower limb balance in patients undergoing total knee arthroplasty (TKA) [ 1 , 2 ]. In posterior reference systems, smaller size results in notching in the anterior cortex of the femur, while in anterior reference systems, a smaller size results in flexion gap enlargement and knee instability [ 3 , 4 ]. Therefore, developing reliable strategies to preoperatively predict the appropriate size of TKA components, specifically in patients with sizes outside the normal range, is particularly important.…”
Section: Introductionmentioning
confidence: 99%
“…Correct sizing of total knee arthroplasty (TKA) components is an essential aspect of the procedure. Indeed, implant malalignment or incorrect sizing may lead to early aseptic loosening and failure, instability, over‐stuffing with increased capsular tension and stiffness, or tibial overhang and persistent pain [2, 20, 29]. To better anticipate final implant size in TKA, preoperative templating has traditionally been used as this allows the surgeon to estimate the implant size that will best accommodate each patient’s anatomy [18, 30].…”
Section: Introductionmentioning
confidence: 99%