2018
DOI: 10.30544/403
|View full text |Cite
|
Sign up to set email alerts
|

The effect of calcinated hydroxyapatite and magnesium doped hydroxyapatite as fillers on the mechanical properties of a model BisGMA/TEGDMA dental composite initially and after aging

Abstract: The aim of this study was to investigate the possibility of modifying model BisGMA/TEGDMA dental composite by substituting 10 wt. % of conventional glass fillers with bioactive fillers based on calcinated nanosized hydroxyapatite (HAp) and Mg doped hydroxyapatite (Mg-HAp). HAp and Mg-HAp powders were synthesized hydrothermally. Mechanical properties: hardness by Vickers (HV) and flexural strength (Fs) were tested initially and after being stored for 28 days in simulated body fluid (SBF). The experimental compo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
2

Relationship

2
0

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 23 publications
0
3
0
Order By: Relevance
“…Mg,Cu-HAP could also find application as a restorative dental material (i.e. bioactive dental insert [25], bioactive composite filler [26]). The effects of doped ions on the mechanical properties, biocompatibility, antimicrobial activity and sintering behaviour were also investigated.…”
Section: Introductionmentioning
confidence: 99%
“…Mg,Cu-HAP could also find application as a restorative dental material (i.e. bioactive dental insert [25], bioactive composite filler [26]). The effects of doped ions on the mechanical properties, biocompatibility, antimicrobial activity and sintering behaviour were also investigated.…”
Section: Introductionmentioning
confidence: 99%
“…The inserts' dimension after sintering at 1200°C was measured to be 4.70 mm in diameter and 1.70 mm in thickness. Detailed characterization of the starting powders and sintered compacts used in this study are given in our previous publications 24,25 …”
Section: Methodsmentioning
confidence: 99%
“…Detailed characterization of the starting powders and sintered compacts used in this study are given in our previous publications. 24,25 The phase composition of doped HAP based dental inserts was determined by X-ray diffraction (XRD), conducted on X-ray A field emission scanning electron microscope (SEM) (Tescan FE-SEM Mira 3 XMU) operated at 20 keV was engaged for evaluation of the inserts' surfaces microstructure upon etching with 37% phosphoric acid for 15 s (Scotchbond Universal Etchant, 3M ESPE). Prior to the SEM analysis, all samples were coated with thin layer of gold using a sputter coater (Polaron SC503, Fisons Instruments).…”
Section: Preparation and Characterization Of Mg-and Sr-substituted Ha...mentioning
confidence: 99%