2012
DOI: 10.1007/978-3-642-31271-7_2
|View full text |Cite
|
Sign up to set email alerts
|

The Effect of Amorphous Selenium Thickness on Imaging Performance of Contrast Enhanced Digital Breast Tomosynthesis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
14
0

Year Published

2013
2013
2022
2022

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(15 citation statements)
references
References 19 publications
1
14
0
Order By: Relevance
“…Figure shows a flow chart for the propagation of Φ and S through the DE imaging process according to the CLSM. The detector model was modified with the ability to generate an arbitrary x‐ray spectrum with tube potentials ranging between 23 kVp and 51 kVp and to vary the a‐Se thickness of the detector in an effort to quantify its effect on quantum detective efficiency (QDE) . A projection‐space subtraction step ( Sub ) was also implemented.…”
Section: Theorymentioning
confidence: 99%
See 2 more Smart Citations
“…Figure shows a flow chart for the propagation of Φ and S through the DE imaging process according to the CLSM. The detector model was modified with the ability to generate an arbitrary x‐ray spectrum with tube potentials ranging between 23 kVp and 51 kVp and to vary the a‐Se thickness of the detector in an effort to quantify its effect on quantum detective efficiency (QDE) . A projection‐space subtraction step ( Sub ) was also implemented.…”
Section: Theorymentioning
confidence: 99%
“…For CE‐DBT, structural noise is propagated from 2D to 3D by employing the mathematical methods outlined by Gang et al and added after 2D to 3D conversion of the stochastic NPS. The analysis was generalized for a system without focal spot motion since CE‐DM functions without movement of the x‐ray tube and because for DBT acquisitions implementing filtered backprojection (FBP) reconstruction algorithms (as is the case in the present work), Fourier filters act as the dominant source of blur …”
Section: Theorymentioning
confidence: 99%
See 1 more Smart Citation
“…X‐ray experiments in previous works have validated the MTF degradation due to oblique incidence. The MTF was calculated with a digital breast tomosynthesis (DBT) system using a tungsten edge . Previous works have also shown that increasing the thickness of selenium results in more substantial MTF degradation .…”
Section: Introductionmentioning
confidence: 99%
“…The MTF was calculated with a digital breast tomosynthesis (DBT) system using a tungsten edge . Previous works have also shown that increasing the thickness of selenium results in more substantial MTF degradation . This arises because the incident ray traverses a broader path length through the x‐ray converter, yielding more blurring.…”
Section: Introductionmentioning
confidence: 99%