The effect of a heat and moisture exchanger on gas flow in a Mapleson F breathing system during inhalational induction

Abstract: SummaryHeat and moisture exchangers (HMEs) humidify, warm and filter inspired gas, protecting patients and apparatus during anaesthesia. Their incorporation into paediatric anaesthetic breathing systems is recommended. We experienced delays in inhalational induction whilst using a Mapleson F breathing system with an HME. We have demonstrated that the HME significantly alters gas flow within the breathing system. Approximately half of the fresh gas flow is delivered to the patient, the remainder being wasted in… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
4
0

Year Published

2003
2003
2013
2013

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 6 publications
(3 reference statements)
0
4
0
Order By: Relevance
“…So most of the fresh gas will enter expiratory limb leading to wastage of fresh gases and delaying induction by inhalation agents. [242526]…”
Section: Mapleson F Systemmentioning
confidence: 99%
“…So most of the fresh gas will enter expiratory limb leading to wastage of fresh gases and delaying induction by inhalation agents. [242526]…”
Section: Mapleson F Systemmentioning
confidence: 99%
“…The work of breathing increases when HMEFs are used [113]. The resistance to gas flow of an HMEF added to a Mapleson F breathing system can cause a delay in the induction of anaesthesia [114]. The addition of an HME can cause hypercapnia if the internal volume of the HME is too large [115].…”
Section: Use Of Hmes and Filters With Paediatric Patientsmentioning
confidence: 99%
“…This gradient is suf®cient to allow diversion of fresh gas down the expiratory limb, resulting in failure or delay in gas induction. Goddard reported dif®culty in performing gas inductions when using an Ayres T piece with a ®lter, and this technique 34 was the cause of concern for Marcus and colleagues. 45 71 Da Fonseca and co-workers recommend that the HME should be removed from the Mapleson F breathing system until inhalation induction is complete, or that the reservoir bag is completely occluded unless an effective seal is obtained with the mask.…”
Section: Delay or Failure Of Gas Inductionmentioning
confidence: 99%