2013
DOI: 10.5755/j01.sace.1.2.2778
|View full text |Cite
|
Sign up to set email alerts
|

The Durability Test Method for External Thermal Insulation Composite System used in Cold and Wet Climate Countries

Abstract: The paper proposes the durability prediction method for external thermal insulation composite system (ETICS), which could be applied in cold and wet climate regions. This improved method is based on the international and nowadays applicable standards for systems service life assessment (ETAG 004, ISO 15462), and completes them with other necessary impact criteria. This study examines the main climate exposures and how these impacts reproduced in the laboratories. The paper analyses the extreme air temperature … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0
2

Year Published

2017
2017
2022
2022

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 15 publications
(12 citation statements)
references
References 12 publications
0
8
0
2
Order By: Relevance
“…The lateral surfaces have been waterproof sealed by means of a bituminous layer so that water uptake can only take place by the exposed sample surface. The three samples on the left of Figure 2 have a relatively rough finishing (final render with mineral paint) and are exposed without any protection at an angle of 135 • , which is an extreme exposure compared to the common natural aging tests reported in [25][26][27]. Then there are several other samples with a smooth finishing, with some structures on them as it will be the case for structured façades.…”
Section: Weathering Of the Aerogel-based Rendering Without Reinforcement Meshmentioning
confidence: 99%
“…The lateral surfaces have been waterproof sealed by means of a bituminous layer so that water uptake can only take place by the exposed sample surface. The three samples on the left of Figure 2 have a relatively rough finishing (final render with mineral paint) and are exposed without any protection at an angle of 135 • , which is an extreme exposure compared to the common natural aging tests reported in [25][26][27]. Then there are several other samples with a smooth finishing, with some structures on them as it will be the case for structured façades.…”
Section: Weathering Of the Aerogel-based Rendering Without Reinforcement Meshmentioning
confidence: 99%
“…Veiga e Malanho (2010), Griciute et al (2013) e Kvande et al (2018) ainda destacam que o propósito do ensaio é avaliar a durabilidade do revestimento do isolamento térmico, usualmente argamassado ou plástico, com espessuras de 1 mm até 3 mm. Ou seja, avalia através de ensaio mais agressivo a durabilidade de revestimentos de pequena espessura que protegem isolamentos térmicos que se degradariam na presença de umidade.…”
Section: Referencial Teóricounclassified
“…Verifica-se que o enfoque da ASTM 1185-08 (ASTM, 2016), ETAG 004 (EOTA, 2013), AS/NZS-2908 (NZS, 2000) e ISO 8336 (ISO, 2017) é a avaliação de sistemas construtivos leves, seja com telhas de materiais cimentícios ou de sistemas de isolamento térmico e não para paredes em alvenaria com revestimento argamassado ou em concreto, sistemas construtivos usualmente utilizados no Brasil. Importante destacar a diferença de espessura entre 1 mm e 3 mm do revestimento argamassado ensaiado nos sistemas de isolamento térmico pela ETAG 004 (relatada na bibliografia (KVANDE et al, 2018;GRICIUTE et al, 2013) em relação à espessura de revestimento externo utilizado no Brasil, entre 20 mm e 30 mm, conforme NBR 13749 (NBR, 2013c).…”
Section: Figura 3 Comparativo Da Deformação Real Com a Máxima Permitidaunclassified
“…In the same year, Bochen et al, (2005) performed other climatic chamber tests, also determining the equivalence to natural aging. Years later, Griciuté et al, (2013) made more experimentations involving the accelerated ageing of ETICS.…”
Section: Introduction and State Of The Artmentioning
confidence: 99%