2019
DOI: 10.1109/tpel.2018.2869625
|View full text |Cite
|
Sign up to set email alerts
|

The Dual-Current Control Strategy of Grid-Connected Inverter With LCL Filter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
20
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
8
1
1

Relationship

1
9

Authors

Journals

citations
Cited by 64 publications
(26 citation statements)
references
References 32 publications
0
20
0
Order By: Relevance
“…So doing, the inverter is current-controlled. Different implementations of the regulators H D2 and H D1 can be found in the literature, such as the P-PI [72], [73], P-H ∞ [74], P-PR [31], [37], DB-PI [75], PR-R [76], hysteresis current control (HCC)-PR [77]. These regulators achieve a sufficiently fast response for the inner i L loop and a high-gain in the lower frequency region for the outer loop, beneficial for protection and reference tracking, respectively.…”
Section: B Double-loop Control Structuresmentioning
confidence: 99%
“…So doing, the inverter is current-controlled. Different implementations of the regulators H D2 and H D1 can be found in the literature, such as the P-PI [72], [73], P-H ∞ [74], P-PR [31], [37], DB-PI [75], PR-R [76], hysteresis current control (HCC)-PR [77]. These regulators achieve a sufficiently fast response for the inner i L loop and a high-gain in the lower frequency region for the outer loop, beneficial for protection and reference tracking, respectively.…”
Section: B Double-loop Control Structuresmentioning
confidence: 99%
“…Consequently, the gridside current feedback AD method is selected to realize a virtual resistor in parallel with the filter capacitor. Guan et al [9] proposed a dual-current active damping control strategy based on the feedback of inverter-side and grid-connected currents. Nonetheless, the equivalent virtual impedance to be simulated in series with a filter inductance will decrease the stability margin.…”
Section: Introductionmentioning
confidence: 99%
“…The Grid-Connected Inverter (GCI) is an important interface unit inserted between renewable energy and the grid [1], where a power filter, such as L, LC, and LCL, is also indispensable to suppress the harmonic current generated by the high frequency switching. Compared with the L and LC filter, the LCL filter is often utilized in industry, owing to its better harmonic attenuation performance and lower cost [2], [3].…”
Section: Introductionmentioning
confidence: 99%