2004
DOI: 10.1109/tpel.2003.823171
|View full text |Cite
|
Sign up to set email alerts
|

The Double Discontinuous Mode Operation of a Converter: A Method for Soft Switching

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0

Year Published

2007
2007
2022
2022

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 12 publications
(6 citation statements)
references
References 9 publications
0
6
0
Order By: Relevance
“…The proposed converter is composed of controlling devices, a step-up inductor L r , and a snubber capacitor C r used in similar way for the conventional converter. Furthermore, the current flowing through the inductor L r is controlled to be discontinuous [6,7], then the turn-on operation of the switches S 1 and S 2 becomes to be ZCS. The turn-off of the switches is also operated with ZVS by the partial resonant operation.…”
Section: Configuration and Operation Principle Of Proposed Convertermentioning
confidence: 99%
See 1 more Smart Citation
“…The proposed converter is composed of controlling devices, a step-up inductor L r , and a snubber capacitor C r used in similar way for the conventional converter. Furthermore, the current flowing through the inductor L r is controlled to be discontinuous [6,7], then the turn-on operation of the switches S 1 and S 2 becomes to be ZCS. The turn-off of the switches is also operated with ZVS by the partial resonant operation.…”
Section: Configuration and Operation Principle Of Proposed Convertermentioning
confidence: 99%
“…The partial resonant operation makes ZCS or ZVS for the control switches without switching losses so called "soft-switching" [3,4,5]. The switching control technique of the proposed converter is simplified for the switches to drive in constant switching frequency [4,6].…”
Section: Introductionmentioning
confidence: 99%
“…In discontinuous mode, the input ac current becomes a quasi sinusoidal waveform in proportion to the magnitude of input ac voltage under constant switching frequency with PWM. The control circuit for the DCM converter eliminate-es the complicated circuit control requirement and reduces the number of components [4]- [5]. Moreover, in this mode, the turn-on of chopper switching devices occurs at zero current, that is, zero current switching.…”
Section: Introductionmentioning
confidence: 99%
“…The DCM control method is used by a large number of converters, because the control circuit and technique of DCM are simple. Also in discontinuous mode, the ac input current is nearly sinusoidal waveform with the constant duty cycle switching [4,5]. Another merit of this mode is that turn on of switches in converter occurs at zero current switching (ZCS).…”
Section: Introductionmentioning
confidence: 99%
“…As a result of these, the converter brings on low efficiency. To improve these, a large number of soft switching topologies included resonant circuits have been proposed [5,6,7,8]. But these topologies increase number of switching device in circuit and complicate sequence of switching operation.…”
Section: Introductionmentioning
confidence: 99%