2018
DOI: 10.1016/j.measurement.2017.10.043
|View full text |Cite
|
Sign up to set email alerts
|

The device to measuring of the load angle for salient-pole synchronous machine in education laboratory

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(4 citation statements)
references
References 9 publications
0
4
0
Order By: Relevance
“…These methods possible to localize places of faults and it can also serve for the diagnosis and detection of disorders in material quality and other anomalies during operation of the equipment [15], [16].…”
Section: Resultsmentioning
confidence: 99%
“…These methods possible to localize places of faults and it can also serve for the diagnosis and detection of disorders in material quality and other anomalies during operation of the equipment [15], [16].…”
Section: Resultsmentioning
confidence: 99%
“…• Simplicity and Cost Factor: In the proposed strategy of this paper, the variables of V sg , P sg , and Q sg can be easily measured/calculated from the available current and voltage transformers (CT and PT) at the SG terminal, and δ sg param- eter can also be easily estimated by various methods such as an optical encoder which is connected to an encoder of a signal processor [25]. Hence, its application is simple and cost-effective.…”
Section: Comparison Of the Proposed Methods With The Conventional Imp...mentioning
confidence: 99%
“…Meanwhile, as seen from Table 4, the proposed method detects all happened events with an acceptable detection time (just within 1.6 s) than the other schemes especially the impedance‐based relay. Accuracy Factor : As can be seen in Figure 12, during the TPF with lead‐loading condition of the machine, the impedance trajectory enters into the relay zones mistakenly, giving rise to tripping the SG. While, as seen from Table 4, the provided setting‐free protection scheme of this paper does not have any wrong performance during such PSD events and as a result has an accurate performance than the other schemes. Simplicity and Cost Factor : In the proposed strategy of this paper, the variables of V sg , P sg , and Q sg can be easily measured/calculated from the available current and voltage transformers (CT and PT) at the SG terminal, and δ sg parameter can also be easily estimated by various methods such as an optical encoder which is connected to an encoder of a signal processor [25]. Hence, its application is simple and cost‐effective.…”
Section: Comparison Of the Proposed Methods With The Conventional Imp...mentioning
confidence: 99%
“…The methods of determining the generator's load angle in power plants mainly consist of physical measurements. Direct load angle measurements are rarely used, while indirect measurements, utilizing rotor position information from the corresponding sensor and the information about the first harmonic of the generator terminal voltage, such as those presented in [5][6][7], are more prevalent. These methods of load angle determination require installation of additional measuring equipment, which represents additional costs, while in some systems it is even not possible to install it due to their configuration.…”
Section: Introductionmentioning
confidence: 99%