2006
DOI: 10.1541/ieejpes.126.359
|View full text |Cite
|
Sign up to set email alerts
|

The Development and Practical Use of A New 24 kV Dry Air Insulated Switchgear

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
7
0

Year Published

2008
2008
2021
2021

Publication Types

Select...
6
2

Relationship

3
5

Authors

Journals

citations
Cited by 16 publications
(7 citation statements)
references
References 2 publications
0
7
0
Order By: Relevance
“…In these days, most of the medium voltage switchgears are the cubicle-type low pressure SF6 gas insulated switchgears (C-GIS). However, SF6 gas was designated as one of the targets of emission control in the global warming prevention conference held in 1997 (COP3), then research and development of SF6 gas free systems are advanced actively [1][2][3][4][5][6]. In the medium voltage class, the switchgears insulated with high pressure air or nitrogen has been developed [3] On the other hand, research and development of technological components aiming for the realization of a full solid insulated substation is advanced actively in the extra high voltage class.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…In these days, most of the medium voltage switchgears are the cubicle-type low pressure SF6 gas insulated switchgears (C-GIS). However, SF6 gas was designated as one of the targets of emission control in the global warming prevention conference held in 1997 (COP3), then research and development of SF6 gas free systems are advanced actively [1][2][3][4][5][6]. In the medium voltage class, the switchgears insulated with high pressure air or nitrogen has been developed [3] On the other hand, research and development of technological components aiming for the realization of a full solid insulated substation is advanced actively in the extra high voltage class.…”
Section: Introductionmentioning
confidence: 99%
“…Under the situation mentioned above, a solid insulated switchgear (SIS), in which main circuit including a vacuum interrupter are coated with epoxy resin, has been developed [2]. However, improvement of the surface insulation performance of the solid/gas composite insulation system is required for the development of higher stress and compact design.…”
Section: Introductionmentioning
confidence: 99%
“…This paper describes PD detection characteristics of the PD monitoring system developed for our new C-GIS products in which a compressed dry air, known as a greenhouse gas [4]- [6], is used as insulation. The shield conductor embedded in bushing is utilized as a PD sensor and the sensitivity is investigated in the frequency range from VHF to UHF.…”
Section: Main Conductormentioning
confidence: 99%
“…On the other hand, we have developed the electromagnetically actuated vacuum circuit breaker (VCB) for the improvement of reliability by reducing the number of parts and planned to launch it into market [2,3]. To achieve CBM for the VCB, a monitoring device to monitor state of device and a system to diagnose monitoring result are indispensable.…”
Section: Introductionmentioning
confidence: 99%