The Determination of the Fluorescence Lifetimes of Dissolved Substances by a Phase Shift Method

Abstract: The lifetimes of fluorescent substances are determined by exciting the fluorescence with light modulated at a high frequency and measuring the difference in phase between the exciting light and the resulting fluorescence. The exciting light is modulated by an ultrasonic standing wave in a liquid which causes the latter to act as an intermittent diffraction grating. Photomultiplier tubes are used to pick up the exciting and fluorescent light. Tuned circuits are used to isolate a single harmonic of the signal fr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
22
0
2

Year Published

1954
1954
2019
2019

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 144 publications
(24 citation statements)
references
References 3 publications
0
22
0
2
Order By: Relevance
“…It was already shown in 1933 [ 15] that if this intensity modulated light beam were to excite an atomie Al ready in the mid-fifties lifetimes of ftuorescing substances in the ns range were measured via this phase shift metbod with 1% or better precision [ 16,17]. Nowadays the phase shift metbod is still in use to distinguish species on the basis of their lifetime in twodimensional ftuorescence imaging [ 18].…”
Section: The Experimental Metbodmentioning
confidence: 99%
“…It was already shown in 1933 [ 15] that if this intensity modulated light beam were to excite an atomie Al ready in the mid-fifties lifetimes of ftuorescing substances in the ns range were measured via this phase shift metbod with 1% or better precision [ 16,17]. Nowadays the phase shift metbod is still in use to distinguish species on the basis of their lifetime in twodimensional ftuorescence imaging [ 18].…”
Section: The Experimental Metbodmentioning
confidence: 99%
“…Lifetime of the excited fluorophores in the foil relative to the excitation light is a much better measurement of oxygen quenching than intensity. Lifetime is measured, indirectly, by the phase delay between the excitation and emission (Bailey and Rollefson 1953). An additional red LED is included as a non-excitation reference as a means to compensate for potential drift in the electronics of the transmitter and receiver circuit.…”
Section: Introductionmentioning
confidence: 99%
“…This is somewhat surprising in that phase-modulation fluorometers were constructed prior to the development of time-domain instruments [10][11][12][13][14].…”
Section: I Introductionmentioning
confidence: 99%