The determination of low d5‐phenylalanine enrichment (0.002–0.09 atom percent excess), after conversion to phenylethylamine, in relation to protein turnover studies by gass chromatography/electron ionization mass spectrometry

Abstract: A gas chromatography/mass spectrometry (GC/MS) method for measuring very low levels of enrichment of d5-phenylalanine (0.002-0.09 atom percent excess) is described. This method makes it possible to determine the enrichment of amino acid incorporated into tissue protein during studies of protein synthesis in man. Phenylalanine is enzymatically converted to phenylethylamine and the d5-enrichment is measured in the heptafluorobutyryl derivative by selective-ion recording under electron ionization conditions. The … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
106
0

Year Published

1995
1995
2014
2014

Publication Types

Select...
10

Relationship

1
9

Authors

Journals

citations
Cited by 158 publications
(106 citation statements)
references
References 5 publications
0
106
0
Order By: Relevance
“…The intracellular concentration of phenylalanine was then calculated from the tissue value, accounting for the ratio of intracellular to extracellular water (21). Mixed muscle protein-bound phenylalanine enrichment was measured by GCMS (GC 8000 series, MD 800, Fisons Instruments, Manchester, UK) using the standard curve approach previously described (22).…”
Section: Methodsmentioning
confidence: 99%
“…The intracellular concentration of phenylalanine was then calculated from the tissue value, accounting for the ratio of intracellular to extracellular water (21). Mixed muscle protein-bound phenylalanine enrichment was measured by GCMS (GC 8000 series, MD 800, Fisons Instruments, Manchester, UK) using the standard curve approach previously described (22).…”
Section: Methodsmentioning
confidence: 99%
“…standard (43). Mixed-muscle protein-bound phenylalanine enrichment was analyzed by GC-MS after protein hydrolysis and amino acid extraction (43), using the external standard curve approach (7).…”
Section: Methodsmentioning
confidence: 99%
“…The tracer laboratories and suppliers of tracer MS, therefore, should focus on the development of improved equipment and methodology that either allows the measurement of lower enrichments with GC-MS equipment or improves the sensitivity of the existing GC-combustion-IRMS equipment. An elegant solution of the first type has been presented by Calder et al (1992). In the case of tracers with multiple heavy atoms (e.g.…”
Section: Amino Acid Incorporation Methods To Measure Protein Synthesimentioning
confidence: 99%