2017
DOI: 10.1039/c7ay01065f
|View full text |Cite
|
Sign up to set email alerts
|

The determination of chlorine in plastic using isotope dilution inductively coupled plasma mass spectrometry

Abstract: The determination of chlorine (Cl) in plastic using isotope dilution inductively coupled plasma mass spectrometry (ID-ICPMS) combined with different sample pretreatment procedures was examined in the present study.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 8 publications
(2 citation statements)
references
References 30 publications
0
2
0
Order By: Relevance
“…39 Furthermore, a mass-shift approach using DRC with H 2 as the reaction gas has been used to shift 35 Cl to 35 Cl 1 H 1 H + and 37 Cl 1 H 1 H + , leading to lower LODs. 44,45 In addition to chlorine, DRC has also been used to eliminate interferences for bromine and iodine determination by using H 2 as a reaction gas. 46,47 In the case of 129 I determination, isobaric interference by 129 Xe, a common contaminant in Ar gas, can be removed by using O 2 as a reaction gas.…”
Section: Reaction/collision Cells: Minimizing Spectral Interferencementioning
confidence: 99%
See 1 more Smart Citation
“…39 Furthermore, a mass-shift approach using DRC with H 2 as the reaction gas has been used to shift 35 Cl to 35 Cl 1 H 1 H + and 37 Cl 1 H 1 H + , leading to lower LODs. 44,45 In addition to chlorine, DRC has also been used to eliminate interferences for bromine and iodine determination by using H 2 as a reaction gas. 46,47 In the case of 129 I determination, isobaric interference by 129 Xe, a common contaminant in Ar gas, can be removed by using O 2 as a reaction gas.…”
Section: Reaction/collision Cells: Minimizing Spectral Interferencementioning
confidence: 99%
“…67 This approach was also applied together with ICP-QQQ in mass-shift mode using H 2 as a reaction gas for chlorine determination. 45 Highly sensitive and precise chlorine isotope ratio measurements were performed without interferences, such as 16 O 18 O 1 H and 36 Ar 1 H on 35 Cl and 37 Cl, respectively. 45 Finally, it is important to mention that the determination of halogens has been an important task for more than 40 years 87-92 but it has received increased attention in recent years, especially with the development of multi-element techniques, such as ICP-MS.…”
Section: Internal Standards and Isotope Dilution For Halogen Determmentioning
confidence: 99%