2018 Electrical Power, Electronics, Communications, Controls and Informatics Seminar (EECCIS) 2018
DOI: 10.1109/eeccis.2018.8692988
|View full text |Cite
|
Sign up to set email alerts
|

The Design of Radial Flux Permanent Magnet Generator on Low Speed Wind Turbine to Reduce Cogging Torque

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0
2

Year Published

2020
2020
2023
2023

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(6 citation statements)
references
References 9 publications
0
4
0
2
Order By: Relevance
“…4 shows the cogging torque waveforms and harmonic spectra of the two AMPG topologies obtained by means of a TWM FEA (š‘ = 150), which requires about 90 minutes to be performed. Note that the orders of the AHCs agree with (19) and (20). Moreover, the amplitude of the NHCs is negligible if compared with the amplitude of the AHCs.…”
Section: A Results Using the Design Formulamentioning
confidence: 65%
See 1 more Smart Citation
“…4 shows the cogging torque waveforms and harmonic spectra of the two AMPG topologies obtained by means of a TWM FEA (š‘ = 150), which requires about 90 minutes to be performed. Note that the orders of the AHCs agree with (19) and (20). Moreover, the amplitude of the NHCs is negligible if compared with the amplitude of the AHCs.…”
Section: A Results Using the Design Formulamentioning
confidence: 65%
“…The minimization of the NHCs of the cogging torque in one-piece stator PMMs has been addressed using rotor or stator skewing [13], [14], dummy slots or notches on the tooth tips [15], [16], slot openings design [17], [18] and teeth pairing [19], [20]. Both analytical and meta-heuristic approaches are adopted to determine the optimal design solutions.…”
Section: Introductionmentioning
confidence: 99%
“…Besides, to bear the radial force, which is ten times greater than the shear stress, substantial and expensive rotor and stator structures are nonetheless necessary [6]. Therefore, a decrease in output power is caused by cogging1torque1in1radial1flux1permanent1magnet1generators [7].…”
Section: Radial Permanent Magnet Flux Generatormentioning
confidence: 99%
“…Hal tersebut menyebabkan energi celah udara dapat diminimalkan. Nilai torsi denyut (Ļ„) dapat dibuat mendekati nol berdasarkan persamaan (6).…”
Section: B Desain Pemasangan Lebar Gigi-gigi Statorunclassified
“…Penelitian [6] menggunakan topologi desain stator ganda pada generator magnet permanen fluks radial untuk parameter kecepatan angin 5 m/s. Stator ganda merupakan kombinasi dari generator magnet permanen fluks radial dengan inner-stator dan outer-stator.…”
unclassified