2022
DOI: 10.1007/s12350-021-02620-y
|View full text |Cite
|
Sign up to set email alerts
|

The current status of CZT SPECT myocardial blood flow and reserve assessment: Tips and tricks

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
25
0
10

Year Published

2022
2022
2023
2023

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 36 publications
(40 citation statements)
references
References 71 publications
0
25
0
10
Order By: Relevance
“…The main products on the market are represented by the D-SPECT and VERITIONTM cameras (Spectrum Dynamics, Palo Alto, CA, USA) and by the Discovery NM 530c and NM/CT 670 CZT NM/CT 570c cameras (GE Healthcare, Haifa, Israel). All of this equipment is capable of performing dynamic SPECT in order to assess myocardial blood flow (MBF) [62].…”
Section: Development and Application Of High-resolution Czt Camerasmentioning
confidence: 99%
“…The main products on the market are represented by the D-SPECT and VERITIONTM cameras (Spectrum Dynamics, Palo Alto, CA, USA) and by the Discovery NM 530c and NM/CT 670 CZT NM/CT 570c cameras (GE Healthcare, Haifa, Israel). All of this equipment is capable of performing dynamic SPECT in order to assess myocardial blood flow (MBF) [62].…”
Section: Development and Application Of High-resolution Czt Camerasmentioning
confidence: 99%
“…Finally, another experience from Zavadovsky et al, analysing the state-of-the-art MBF assessment with CZT SPECT and technical issues related to image acquisition, data post-processing and interpretation, concluded that standardization of acquisition and postprocessing protocols are needed in order to reduce inter-sites variability and increase the clinical relevance of CZT SPECT results [39].…”
Section: Single-photon Emission Computed Tomographymentioning
confidence: 99%
“…7,8,10, 12 Zavadovsky et al reported that MFR may be clinically more powerful than MBF because of several factors, including potential inaccurate extraction fraction correction, the lack of attenuation correction, differences in spatial resolution, and higher image noise. 23 Considering the attenuation of the patient was similar between stress and rest, the MFR obtained by dividing the tracer uptake during the stress scan by that during the resting scan may cancel the effects of the attenuation. Moreover, a recent study reported that the MFR value of each coronary artery obtained through CZT-SPECT correlates with invasive FFR.…”
Section: Analyzing Each Coronary Artery Territorymentioning
confidence: 99%